Calibrating Depth
Scale
The depth scale on the infeed table can be cali-
brated or "zeroed" if it is not correct.
Tools Needed
Straightedge ...................................................... 1
Phillips Screwdriver ........................................... 1
To calibrate the depth scale:
1.
DISCONNECT
THE
FROM THE POWER SOURCE!
2.
Set the outfeed table height as described in
the Setting Outfeed Table Height instruc-
tions on Page 18.
3.
Use the straightedge to help adjust the infeed
table exactly even with the outfeed table, as
shown in Figure 65.
4.
Using a screwdriver, adjust the scale pointer
to zero (Figure 66).
-46-
Qty
JOINTER/PLANER
Pulley Alignment
Figure 67. Fence and V-belt cover removed.
2.
Place a 2" C-clamp on each pulley so the
adjustment shaft faces out, place a straight-
edge on the clamps, as shown in Figure 68,
and visually check pulley alignment.
Figure 68. Checking belt alignment.
G0633/G0634 Jointer/Planer Combo Machine