Operation - AEG 69802 G Operating Instructions Manual

Hide thumbs Also See for 69802 G:
Table of Contents

Advertisement

Operation

Hob burners
To light a burner:
Push in the relevant control knob
!
and turn it to maximum position.
Upon ignition, keep the knob
!
pushed down about 5 seconds.
This
"thermocouple" (see diagram-
letter D) to be heated and the
safety device to be switched off,
otherwise the gas supply would
be interrupted.
Then adjust the flame as required.
!
If the burner does not ignite, turn the control knob to zero, and try again.
!
Each control knob is equipped with a pilot light which gradually lights up
according to the heat level that you select with the control knob.
When switching on the mains, after installation or a power cut, it is quite
normal for the spark generator to be activated automatically.
To ensure maximum burner efficiency, you should only use pots and pans
with a flat bottom fitting the size of the burner used (see table).
Burner
Large (rapid)
Medium (semi-rapid)
Small (Auxiliary)
As soon as a liquid starts boiling, turn down the flame so that it will barely
keep the liquid simmering.
If you use a saucepan which is smaller than the recommended size, the
flame will spread beyond the bottom of the vessel, causing the handle to
overheat.
Take care when frying food in hot oil or fat, as the overheated splashes could
easily ignite.
If the control knobs become difficult to turn, please contact your local Service
Force Centre.
6
will
allow
the
minimum
diameter
160 mm.
120 mm.
80 mm.
A - Burner cap
B - Burner crown
C - Ignition electrode
D - Thermocouple
maximum
diameter
260 mm.
220 mm.
160 mm.

Advertisement

Table of Contents
loading

Table of Contents