Adjusting the Laser Beam Width

You can select the laser beam width used by the DT-970. Note that using this function
may result in a laser beam width error.
In this event, use the procedure below to adjust the laser beam width.
1. Turn the Handheld Terminal ON with the
system menu.
2. Press the following keys in order to start
up laser beam adjustment:
4: ENVIRONMENT
4: BARCODE
4: CALIBRATION
3. Press the trigger key to emit the laser
beam, and align the laser beam with the
beam width adjustment bar code.
* Align the laser beam with the fi ne bars
on both sides of the adjustment bar
code.
(Example)
When the buzzer sounds and the laser
beam turns off, beam width adjustment is
completed.
E-36