Zoneline
Chassis Nomenclature
®
The Zoneline chassis is identified by a model number defining
the type of unit, cooling capacity, electrical information and
optional features included on the unit. When specifying or
ordering the Zoneline chassis use of this nomenclature will
assure receiving the correct unit.
Receptacles/Sub-Bases
Tandem
Perpendicular
230/208V 15 Amp
230/208V 20 Amp
NEMA6-15R
NEMA6-20R
Sub-bases
RAK204U
Voltage
N/A
Amps
N/A
Receptacle
N/A
230/208 Volt sub-bases include appropriate power cord kit.
265 Volt units are to be direct connected. Cordset through enclosed chaseway into interior sub-base receptacle meets the NEC requirements.
Power connection kits are required on all Zoneline
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the
building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent
connection kit would be used. 265 volt cord set units must be installed in compliance with National Electrical Code
Power connection kits
Required on all models.
See specification sheet
for heater KW and branch
circuit ampacity.
230/208 volt
LCDI Power Connection Kit
RAK3153*
Heater KW
2.4/2.32
Watts
2,400/2,320
BTUH
8,150/7,900
Amps
11.0/11.6
Min. circuit amps
Recommended
15 amp
protective
time delay
device
fuse or breaker
230/208 volt
RAK4157
Heater KW
2.4/2.32
Watts
2,400/2,320
BTUH
8,150/7,900
Amps
11.0/11.6
Min. circuit amps
Recommended
15 amp
protective
time delay
device
fuse or breaker
* RAK3153, RAK3203 and RAK3303 will be transitioning to RAK3153A, RAK3203A and RAK3303A respectively. Old and new models are interchangeable, and there will be no change in performance.
**To be used with sub-base
†To be used with sub-base or connection to building wiring
Preliminary specifications subject to change.
52
Large tandem
230/208V 30 Amp
NEMA6-30R
RAK204D15P
RAK204D20P
230/208
15
NEMA6-20R
RAK3153/3203/3303
230/208 volt line cord
connection kit
Line cord connected units
RAK3203*
RAK3303*
3.3/3.2
3,300/3,200
4,700/4,530
11,200/10,900
16,000/15,450
15.1/16.0
21.2/22.4
15
20
20 amp
time delay
time delay
fuse or breaker
fuse or breaker
Direct connection kit†
RAK4207
RAK4307
3.3/3.2
3,300/3,200
4,700/4,530
11,200/10,900
16,000/15,450
15.1/16.0
21.2/22.4
15
20
20 amp
time delay
time delay
fuse or breaker
fuse or breaker
EXAMPLE
A
Z
6
Chassis series
Zoneline
41= deluxe line cool/
packaged
electric heat
terminal
61= deluxe line
chassis
heat pump
Unit type
E= cooling with electric
resistance heat
H= heat pump with electric
resistance heat
265V 15 Amp
265V 20 Amp
NEMA7-15R
NEMA7-20R;
RAK204D30P
230/208
230/208
20
30
NEMA6-20R
NEMA6-30R
chassis (see chart below).
®
RAK4157/4207/4307
230/208 volt universal
power supply kit
265 volt Permanent connected units** (Cord set)
RAK5172
4.7/4.53
2.4
2,400
8,150
9.6
30
15
30 amp
15 amp
time delay fuse
265 volt Direct connection kit†
RAK5157
4.7/4.53
2.4
2,400
8,150
9.6
30
15
30 amp
15 amp
time delay fuse
1
H
1
2
Nominal cooling capacity
07=7,000 BTUH cooling
09=9,000 BTUH cooling
12=12,000 BTUH cooling
15=15,000 BTUH cooling
Voltage/Phase/
Frequency
D= 230/208 Volt, single
phase, 60 Hz
E= 265 Volt, single phase,
60 Hz
265V 30 Amp
NEMA7-30R;
RAK204E15
RAK204E20
265
265
15
20
NEMA7-15R
NEMA7-20R
.
®
RAK5157/5207/5307
265 volt universal power
supply kit
RAK5202
RAK5302
3.4
4.8
3,400
4,800
11,550
16,350
13.3
18.6
20
30
20 amp
30 amp
time delay fuse
time delay fuse
RAK5207
RAK5307
3.4
4.8
3,400
4,800
11,550
16,350
13.3
18.6
20
30
20 amp
30 amp
time delay fuse
time delay fuse
D
A
D
Universal
power connection
Special Features
B=base unit
C=corrosion treated
D= internal
condensate
removal (ICR)
system (heat
pump models
only) (not for
coastal areas)
P=Dry Air 25
RAK204E30
265
30
NEMA7-30R