Chapter 3
Installing the Cisco ASR 903 Router
The Cisco ASR 903 Router power supplies are hot-swappable. If you have installed redundant power
Note
supply modules, you can replace a single power supply without interrupting power to the router.
To avoid erroneous failure messages, allow at least 2 minutes for the system to reinitialize after a power
Caution
supply has been removed or replaced.
When you install the unit, the ground connection must always be made first and disconnected last.
Warning
Statement 1046
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning
Follow these steps to remove and replace the DC power supply on the Cisco ASR 903 Router:
Before servicing the power supply, switch off the circuit breaker in your equipment area. As an
Step 1
additional precaution, tape the circuit-breaker switch in the Off position.
Slip on the ESD-preventive wrist strap that was included in the accessory kit.
Step 2
Switch the power supply circuit-breaker switch to the Off (O) position.
Step 3
Pull the terminal block plug connector out of the terminal block head in the power supply.
Step 4
Loosen the captive screws on the DC power supply.
Step 5
Step 6
Grasping the power supply handle with one hand, pull the power supply out from the chassis while
supporting it with the other hand.
Replace the DC power supply within 5 minutes. If the power supply bay is to remain empty, install a
Step 7
blank filler plate (Cisco part number A900-PWR-BLANK) over the opening, and secure it with the
captive installation screws.

Installing the AC power Supply

The following sections describe how to install a AC power supply in the Cisco ASR 903 Router:
OL-25178-03
Installing the AC Power Supply Module, page 3-28
Activating the AC Power Supply, page 3-28
Cisco ASR 903 Router Hardware Installation Guide