Step
Action
Enter [6] (Receiver Enable). Enter [1] to enable, or [0] to disable.
5
Enable the receiver if RF transmitters or wireless keypads are
programmed into the control.
Note: Make sure the number of receivers set for Enable (1) does not
exceed the capacity of the control panel.
Press the [✱] key to continue.
Enter [7] (Transmitter Module Enable). Enter [1] to enable, or [0]
6
to disable. Enter [1] if bi-directional devices are being used.
Note: If the House ID Source is System and more than one 6150RF
is used, make sure only one has the Transmitter Module
enabled. See Note under House ID Source step 4.
Press the [✱] key.
Enter [0] (High-Security Mode). To put the system into High-
7
Security mode, enter [1]. Enter [0] to disable.
Press the [✱] key to exit the 6150RF Program mode.
8
Note:
This is all the 6150RF programming necessary for this application. Upon exiting the Program mode,
the 6150RF alternately flashes "Ad," the 2-digit keypad address, and the 2-digit receiver address. If
either of these is incorrect, repeat steps 1 through 3.
Programming for an Installation WITH Local Wireless Keys
The 6150RF is supplied with default settings for the functions of the wireless keys. See page 3.
If, during the programming of the wireless keys, you make a wrong entry and want to reprogram a
wireless key, simply press the [✱] key until "d-" is displayed. Then enter the correct information.
Perform steps 1-6 in the Programming for an Installation Without Local Wireless Keys section. Then perform
the following steps:
Step
Action
Enter [3] (House ID). Enter the 2-digit House ID for the 6150RF (01-
1
31).
Note: The House ID is needed only if RF keypads and/or bi-
directional units are used and House ID source is set for Local.
The House ID entered here MUST match the House ID
programmed in the RF keypad and the bi-directional unit.
Press the [✱] key to continue.
Enter [8] (Wireless Key Auto Enroll). The 6150RF automatically
2
advances to first available device number.
Note: If all 8 devices have been enrolled, the 6150RF beeps three
times and continues to alternately flash "oo" and "--."
Press any button on the wireless key to enroll the serial number.
3
Note: If enrolling a wireless key (5804E) in high-security mode, press
all four buttons on the wireless key simultaneously.
Press the [✱] key to accept the serial number; OR press the [#] key
4
to reject the serial number.
If you accept the serial number, the 6150RF beeps twice. If you
reject the serial number, the 6150RF returns to the "enroll serial
number" prompt.
Note: A maximum of 8 wireless keys may be enrolled into the
6150RF. These wireless keys DO NOT occupy any zones
supported by the control.
If you are finished programming for now, press [✱] to exit.
Otherwise, continue with step 5.
Enter [2] (User Code). Enter the 4-digit user code for the wireless
5
key.
Note: The user code must be a valid code that is programmed in the
control panel.
Press the [✱] key to accept the user code.
If you are finished programming for now, press [✱] to exit.
Otherwise, continue with step 6.
Display
Alternately flashes "r-" and
either "1" or "0."
Alternately flashes "tE" and
either "1" or "0."
En
"READY" or "NOT READY"
Display
Alternately flashes "hl" and a
2-digit number.
Alternately flashes "d" with
the device number; and "--."
Alternately flashes "d" with
the device number and the
serial number.
If you accept the serial
number, the display flashes
the device number and a
hyphen.
If you reject the serial
number, the display
alternately flashes "d" with
the device number; and "--."
Flashes "u4." Once the 4-digit
user code is entered, the
display flashes "u4," the first
two digits, and then the last
two digits of the user code.
- 5 -