Dell PowerEdge VRTX Reference Manual page 77

Chassis management controller version 1.0 for dell poweredge vrtx racadm command line reference
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

racadm raid get controllers -o -p name,status
racadm raid get vdisks -o -p layout,status
racadm raid get controllers:RAID.ChassisIntegrated.1-1
racadm raid get controllers:RAID.ChassisIntegrated.1-1 -
p status
racadm raid resetconfig:RAID.ChassisIntegrated.1-1
racadm raid exportlog:RAID.ChassisIntegrated.1-1 -l
<CIFS or NFS share> -u <user name> -p <password> [-f
<filename>]
racadm raid forceonline:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
racadm raid deletevd:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1
racadm raid blink:Disk.Virtual.0:RAID.ChassisIntegrated.
1-1
racadm raid clearconfig:RAID.ChassisIntegrated.1-1
racadm raid importconfig:RAID.ChassisIntegrated.1-1
racadm raid ccheck:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1
racadm raid cancelcheck:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1 {-pdkey:<comma separated PD
FQDDs> | {-vdkey:<comma separated VD FQDDs>}
racadm raid unblink {-pdkey:<comma separated PD FQDDs> |
-vdkey:<comma separated VD FQDDs>}
racadm raid patrolread:RAID.ChassisIntegrated.1-1 [-mode
{auto | manual | disabled}] [-state {start | stop}]
racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1 -assign {yes | no} -type
{ ghs | dhs} -vdkey:<FQDD of VD>
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.
1-1 -speed { fast | full } racadm raid
cancelinit:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid assignva:<VA FQDD> -vdkey:<FQDD of VD> -
accesspolicy { na | rw }
racadm raid createvd:RAID.ChassisIntegrated.1-1 -rl {r0|
r1|r5|r6|r10|r50|r60} [-wp {wt|wb}] [-rp {nra|ra|ara}]
[-ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|
8M|16M}] -pdkey:<comma separated PD FQDDs>
[-dcp {enabled|disabled|default}] [-name <VD name>] [-
size <VD size> {b|k|m|g|t}] [-cc]
racadm raid discardcache:RAID.ChassisIntegrated.1-1
racadm raid changepolicy:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1 -wp {wt|wb} -rp {nra|ra|
ara} -dcp {enabled|disabled|default} racadm raid
rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name
<VD name>
racadm raid ctrlprop:RAID.ChassisIntegrated.1-1 [-
rebuild <value>>] [-bgi <value>] [-reconstruct <value>]
[-checkconsistency <value>] [-ccmode {abortonerror |
normal}] [-copybackmode {off | on | onwithsmart}] [-lb
{auto | disabled}] [-prunconfigured {yes | no}] racadm
raid rebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1 racadm raid
cancelrebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
77

Advertisement

Table of Contents
loading