Input
Example
NOTE: The general format of an alert descriptor:
cmc.alert.category.[subcategory].[severity]
where, category is mandatory, but subcategory and severity are optional. A severity
cannot precede a subcategory.
Valid category values are:
•
System
•
Config
•
Updates
•
Storage
•
Audit
Valid severity values are:
•
Critical
•
Warning
•
Informational
Valid examples of alert descriptors are:
•
cmc.alert.all
•
cmc.alert.audit
•
cmc.alert.audit.lic
•
cmc.alert.audit.warning
•
cmc.alert.audit.lic.critical
•
get - Displays the list of event filter settings.
•
set - Configures the actions and notifications for a given event filter
configuration.
•
-c - Alert descriptor of the specific event filter.
•
-n - The notification to be sent when the event occurs. Valid values are all, snmp,
ipmi, lcd, email, or none. You can append multiple notifications separated by a
comma. You cannot enter the values all or none with other notifications.
•
-r - Event generation interval. This is applicable only to the temperature statistics
subcategory - tmps. You can use this option as a stand-alone or with -n .
NOTE: If both event generation interval and notifications are configured and there is
an error while configuring the notifications, the event generation interval is not set.
The valid values are from 0–365. 0 disables the event generation.
•
Display all available event filter configurations:
racadm eventfilters get -c cmc.alert.all
•
Display eventfilter configurations for a specific category. For example, audit:
racadm eventfilters get -c cmc.alert.audit
•
Display eventfilter configurations for a specific subcategory. For example,
licensing under the audit category:
racadm eventfilters get -c cmc.alert.audit.lic
•
Display eventfilter configurations for a specific severity. For example, warning
under the audit category:
racadm eventfilters get -c cmc.alert.audit.warning
29