NOTE: To use this, you must have the Chassis Administrator privilege.
Synopsis
racadm racreset [-m <module>] [-c <feature>]
Input
•
•
Example
•
•
racresetpcie
Description
Synopsis
raid
Description
Allows you to execute commands to control RAID arrays.
To use this subcommand for CMC you must have Chassis Administartor privilege.
Synopsis
racadm raid
Example
•
Monitor Health of Storage root node
racadm raid get status
Storage Root Node Status : Ok
This command retrieves the controllers keys, (FQDDs.)
68
-m : <module> — Must be one of the following values:
–
chassis — default state, if -m is not specified.
–
server-n, where n=1–4
-c : <feature> — Must be one of the following values:
–
ad — Reset Active Directory properties to the default value. The default setting is
"disabled".
–
pcap — Reset Power Cap properties to the default value.
–
flex — Reset FlexAddress properties to the default value. The default setting is
"enabled".
–
dpse — Reset Dynamic Power Supply Engagement to the default value. The default
setting is "disabled".
NOTE: The –c option is valid with only <module=chassis>.
Perform reset of configuration data to defaults for server-1 module
racadm racresetcfg -m server-1
Perform reset of power cap feature.
racadm racresetcfg -c pcap
Resets the PCIe devices in the chassis to factory defaults.
NOTE: To use this subcommand for CMC, you must have the Chassis Administrator
privilege.
racadm racresetpcie