Convertible Dehumidifier Controller
The H808C Dehumidifier Controller provides automatic
low voltage control of dehumidifiers in central heating
systems. The humidity controller has an spst, snap-acting,
dust-proof switch and is designed for wall or surface duct
mounting.
MODELS:
H808C1029: Premier White™.
H808C1037: Beige.
ELECTRICAL RATING: 50 VA at 24 Vac.
MAXIMUM AMBIENT TEMPERATURE: 125 F [52 C].
SWITCH DIFFERENTIAL: 5 percent RH, nonadjustable.
SET POINT ADJUSTMENT RANGE: 20 to 80 percent
RH; positive ON and OFF positions.
CAUTION
1. Installer must be a trained, experienced service
technician.
2. Disconnect power supply before beginning
installation.
3. Conduct a thorough checkout before leaving
installation.
WALL MOUNTING
1. Locate the humidity controller about 5 ft [1.5m]
above the floor on an inside wall.
NOTES:
a. Be sure the humidity controller is subject to average
room temperature and average relative humidity.
The maximum temperature at the location selected
must not exceed 125 F [52 C].
b. The humidity controller can be mounted directly on
the wall.
2. Drill a small hole in the wall.
3. Run low voltage wiring to the location and pull about
6 in. [152 mm] of wire through the hole.
NOTE: Plug the opening to prevent drafts from affecting
humidity controller operation.
Application
Installation
J.F. • 3-94 • ©Honeywell Inc. 1994 • Form Number 69-0821
1
4. Remove the humidity controller assembly by prying
with a screwdriver in the notch on the bottom of the case
(Fig. 1).
5. Position the case horizontally over the wires with the
arrows on the tabs pointing up and secure the case to the
wall using the two screws provided.
6. Connect the wires to the humidity controller assem-
bly using leadwires and wire nuts provided (see Wiring
section and Fig. 2).
7. Tuck the wires into the bottom of the case.
8. Snap the cover assembly into the case (Fig. 2).
Fig. 1—Removing humidity controller assembly
from case.
Fig. 2—Wiring connections on humidity
controller.
QUICK-CONNECT
WIRE LEAD
COVER
WIRE
NUT
HUMIDIFIER
LEADWIRE
CASE
UP
MOUNTING
HOLE (2)
H808C
M9262
UP
UP
M9263
69-0821

Advertisement

loading

Summary of Contents for Honeywell H808C

  • Page 1 3. Run low voltage wiring to the location and pull about 6 in. [152 mm] of wire through the hole. MOUNTING NOTE: Plug the opening to prevent drafts from affecting HOLE (2) humidity controller operation. M9263 J.F. • 3-94 • ©Honeywell Inc. 1994 • Form Number 69-0821 69-0821...
  • Page 2 DUCT MOUNTING 7. While holding wire in place, mount the case on the 1. Locate the humidity controller at least 8 in. [203 mm] duct using the two mounting screws provided. upstream of the humidifier in the return air duct. NOTE: Tighten the screws firmly so the gasket seals the NOTE: If mounting near an elbow area, keep the humidity space between the case and the duct (Fig.
  • Page 3 PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS COIL AS REQUIRED. COIL HEATING DAMPER MOTOR, IF USED. CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION. M18627 Fig. 6—Typical series wiring diagram of H808C with T87F/Q539A combination for dehumidification and mildew control. H808C T87F/Q539A INTERNALSCHEMATIC T87F FIXED COOL...
  • Page 4 Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario M1P 2V9...