Page 3
Fujitsu would like to thank you for purchasing our ETERNUS DX80 S2/DX90 S2 Disk storage system. The ETERNUS DX80 S2/DX90 S2 Disk storage system is designed to be connected to a Fujitsu (PRIMEQUEST or PRIMERGY) or non-Fujitsu servers. This manual describes operation management and maintenance for the ETERNUS DX80 S2/ DX90 S2 Disk storage system.
This chapter describes the components of the ETERNUS DX80 S2/DX90 S2 Disk storage system. ● Chapter 2 Basic Operation This chapter explains how to turn on and off the ETERNUS DX80 S2/DX90 S2 Disk storage system and how to operate the FUNCTION button on the controller enclosure. ● Chapter 3 Setup...
Page 5
ETERNUS DX Disk storage system and/or to CAUTION other users and their property, if the ETERNUS DX80 S2/DX90 S2 Disk storage system is not used properly. This symbol indicates IMPORTANT information for the user to note when IMPORTANT using the ETERNUS DX80 S2/DX90 S2 Disk storage system.
Page 6
ETERNUS DX80 S2/DX90 S2 Disk storage system: - Make sure to disconnect the power when cleaning. - Be careful that no liquid seeps into the ETERNUS DX80 S2/DX90 S2 Disk storage system when using cleaners, etc. - Do not use alcohol or other solvents to clean the ETERNUS DX80 S2/DX90 S2 Disk storage system.
(NIC)", "Converged Network Adaptor (CNA), or "SAS card" depending on the type of server and interface that are used. • Trademark symbols such as ™ and ® are omitted in this document. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 9
Appendix A Event Notification Message List ...........94 Message Format ....................94 A.1.1 E-mail ............................94 A.1.2 Syslog............................96 A.1.3 SNMP ............................99 A.1.4 Host Sense ..........................103 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 10
Common Terms........................104 A.2.2 Error Messages ........................105 A.2.3 Warning Messages........................123 A.2.4 Informational Messages ......................133 A.2.5 Test Messages ........................138 A.2.6 Sense Codes ........................... 138 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 11
Positions of 3.5" drive slots......................58 Figure 5.3 Installation diagram for a host interface (single-controller type) ..........80 Figure 5.4 Installation diagram for host interfaces (dual-controller type)............ 81 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 12
Table 6.1 Time for volume formatting (disk) ....................83 Table 6.2 Rebuild process time (disk) ....................... 84 Table 6.3 Copyback process time (disk) ....................84 ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
3.5" type Operation panel 3.5" disk or 3.5" Solid State Drive (SSD) Flange cover Flange cover Figure 1.2 Front view of a 3.5" type controller enclosure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
■ Dual-controller type Controller (CM#0) Controller (CM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) Figure 1.4 Rear view of a controller enclosure (dual-controller type) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Without a flange cover POWER LED READY LED FAULT LED FUNCTION button MAINT/ID LED CACHE LED Power switch Figure 1.6 Operation panel (3.5" type controller enclosure) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
There is data in the ETERNUS DX Disk storage system cache memory. (green) ■ Drives ● 2.5" drives DRIVE READY LED DRIVE FAULT LED Figure 1.7 2.5" drive ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
DRIVE FAULT • The drive is in error status. (orange) • In response to commands from ETERNUS CLI, the location of the drive is identified. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
• LAN (RMT) port, LAN (MNT) port These ports are RJ-45 connectors for LAN cables. LAN (RMT) port is not used in the EMEA&I region. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 19
A host interface is a board that has interface ports to connect a controller to the server. There are five types of host interfaces: FC, iSCSI 10Gbit/s, FCoE, iSCSI 1Gbit/s, and SAS. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
If a power outage is detected, data in the cache memory is saved to the non-volatile memory in the controller using the SCU. The saved data is retained in the non- volatile memory indefinitely. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
AC power is supplied to the other power supply unit. The power supply unit or the (off) (orange) (orange) (orange) fan in the power supply unit is in error status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
3.5" disk or 3.5" Solid State Drive (SSD) DE-ID (drive enclosure number) display panel Flange cover Flange cover Figure 1.17 Front view of a 3.5" type drive enclosure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
This section describes LEDs, a DE-ID (drive enclosure number) display panel, and drives of the front of the drive enclosure. ■ DE-ID (drive enclosure number) display panel The DE-ID (drive enclosure number) of the drive enclosure is displayed. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
The drive enclosure is in error status. (orange) POWER The drive enclosure is operating normally. (green) ■ Drives ● 2.5" drives DRIVE READY LED DRIVE FAULT LED Figure 1.21 2.5" drive ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
DRIVE FAULT • The drive is in error status. (orange) • In response to commands from ETERNUS CLI, the location of the drive is identified. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
The link between the DI (OUT) port and the destination port has been established. (green) DI (IN) LINKUP The link between the DI (IN) port and the source port has been established. (green) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
The power supply unit or the (off) (orange) (orange) (orange) fan in the power supply unit is in error status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
There are two types of 2U power distribution units: 2U power distribution units that can connect up to six enclosures and 2U power distribution units that can connect up to eight enclosures. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
This turns on and off the power distribution unit. • Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
For 1U power distribution unit Main line switch Figure 2.1 ON position (marked "|") of the main line switches on a 1U power distribution unit ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
For 1U power distribution unit Main line switch Figure 2.3 OFF position (marked "O") of the main line switches on a 1U power distribution unit ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
OFF (marked "O"), turn it back to ON (marked "I") after the POWER LED of the power supply unit has turned off completely. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
AC power is supplied to a power supply unit. The POWER LED on the power supply unit blinks green. The fan revolves at high speed for about 30 seconds. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
Do not turn the main line switches of the power distribution units and the PSU switches on the ETERNUS DX Disk storage system to the OFF posi- tion. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 36
Press the Power switch of the controller enclosure. Drive enclosure Power switch Drive enclosure Controller enclosure The POWER LEDs on the controller enclosure and the drive enclosures are turned on. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
ETERNUS DX Disk storage system and the server while the server is operating, as this may result in the loss of data or prevent data from being saved. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 38
The ETERNUS DX Disk storage system power is turned off. The POWER LEDs on the controller enclosure and the drive enclosures are turned off. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Use the pin that is provided with the ETERNUS DX Disk storage system to push down the FUNCTION button for three seconds. The ETERNUS DX Disk storage system is in maintenance status when the MAINT/ID LED is green. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 40
Use the pin to push down the FUNCTION button for three seconds. The ETERNUS DX Disk storage system is not in maintenance status when the MAINT/ID LED is off. Attach the flange cover. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
"LicenseKey" field of the license label plate. In the Thin Provisioning [License] screen of ETERNUS Web GUI, "Registered" is shown in "Status". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
"LicenseKey" field of the license label plate. In the Thin Provisioning [License] screen of ETERNUS Web GUI, "Registered" is shown in "Status". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
When deletion of the migration paths is complete, change the FC port mode from "Initiator" to "CA" and set the port parameters. Set the host affinity setting to recognize migration destina- tion volumes from the server. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Flexible Tier Volumes (FTVs) cannot be encrypted individually. Rather, the encryption status of TPVs depends on that of the Flexible Tier Pool (FTRP) to which the FTVs belong. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
"Host I/O Monitoring Interval". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 46
*1: The time that is set in the motor-off interval setting of after the access finishes the "Host I/O Monitoring Interval" of the Eco-mode general setting function ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
If the performance of the current RAID groups is not satisfactory due to conflicting volumes, RAID Migration may be used to improve the performance by redistributing the RAID group configuration. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
The RAID group is not registered as the REC Disk Buffer. The RAID group has an unused area that is more than the capacity of the migration source volume. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
RAID group is reduced by the slower drives. • If the drives that configure the target RAID group are SSDs, SSDs must be used when adding drives. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
SAS disks or Nearline SAS disks can be concatenated. • When the concatenation source volume is configured with SSDs, volumes that are configured with SSDs can be concatenated. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 51
When a volume that is using ETERNUS SF AdvancedCopy Manager to run backups is expanded via LUN Concatenation, the volume will need to be registered with ETERNUS SF AdvancedCopy Manager again. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
ETERNUS DX Disk storage system of the previous Master CM’s are taken over by the new Master CM. Figure 4.1 LAN control (switching of the Master CM) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Event notification and status display for the ETERNUS DX Disk storage system can be performed by ETERNUS CLI. When ETERNUS CLI is used, refer to "ETERNUS CLI User’s Guide". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
The status of the ETERNUS DX Disk storage system and the usage status of RAID groups, TPPs, and SDPs can be checked in the Overview screen of ETERNUS Web GUI. Figure 4.3 ETERNUS Web GUI screen ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
When an event occurs in the ETERNUS DX Disk storage system, an SNMP Trap is sent to the SNMP Manager (monitoring server). For more details on event information notified by SNMP Trap, refer to "Appendix A Event Notification Message List" (page 94). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
(host) center REMCS/SNMP (*1) ETERNUS DX Disk storage system *1: SNMP for the EMEA&I region and REMCS for all other regions Figure 4.4 Event notification ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Do not uninstall or move a drive that is already installed. Contact your sales representative or maintenance engineer if a drive needs to be uninstalled or moved. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
To avoid this, allow the packed drive sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new temperature. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 60
Do not stack drives or stand drives on end. • Do not apply external force to the interface connectors. • Do not knock or drop the drives on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Push into the tab of the dummy drive unit and pull it straight out of the drive slot. Dummy drive unit The removed dummy drive unit should be retained for future use. IMPORTANT ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 62
Check that the newly installed drive's DRIVE READY LED lights up green. Repeat Step 3 Step 4 for each additional drive. If a wrist strap is used, remove the wrist strap. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 63
The removed dummy drive unit should be retained for future use. IMPORTANT Install the new drive. Press the catch on the drive lock lever to unlock it. Catch Lock lever ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 64
Set up RAID groups, volumes, hot spares, and Host Affinity settings on the new drives, as required. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
At time of purchase, the installable drive enclosure model may be different from those described. To find the web-site to check the latest version of this manual, refer to "Read Me First". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
Do not handle the drive enclosure roughly or subject it to physical shocks when laying it down. • Do not stack the drive enclosures. • Do not knock or drop the drive enclosure on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Check the DE-ID (drive enclosure number) for the drive enclosure that is to be added in "Target Drive Enclosure", and click the [Next] button. A screen to show how to install the drive enclosure appears. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 68
The M5 centering screws should be inserted in the 1st and 6th holes above the base line of the controller enclosure. 2U rack rail M5 Centering screws (10mm) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 69
(M5 cage nut) (M5 cage nut) 1st position 1st position (M5 pan head screw) (M5 pan head screw) Base line of drive enclosure Rack rails ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 71
Failure to do so may cause injury. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 72
Use two M5 screws to fasten it in the rack pillar. ■ For regions other than EMEA&I Use four M5 screws to fasten it in the rack pillar. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 73
The DE_No. labels are supplied with the ETERNUS DX Disk storage system. Attach the flange cover that is provided with the ETERNUS DX Disk storage system. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 74
Use the thumb screws to attach the brackets to the rack rail (for left side) and the rack rail (for right side). Attachment location of the bracket 3.5" type 2.5" type drive enclosure drive enclosure Bracket Thumb screw ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 75
• For a dual-controller type DI (IN) port DI (IN) port Drive enclosure 1 (Added drive enclosure) Controller enclosure DI (OUT) port DI (OUT) port ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 76
The "■" or "●" symbol is also printed on the destination labels. Carefully check the connection origin and connection destination. Attach the desti- nation labels as shown below: ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 77
ID (drive enclosure number) to the DI (IN) port of IOM6#0 in the drive enclosure that is to be added. Drive enclosure to be added ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 78
Wrap the release tie around the power cord and fasten the release tie from either side. Make sure that the release tie is not loose. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 79
For details on drive installation, refer to "5.1.4 Additional Drive Installation Procedure" (page 61). If a wrist strap is used, remove the wrist strap. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
• Contact your maintenance engineer when a host interface is installed in the host interface 1 (CA#1) of the ETERNUS DX80 S2/DX90 S2. 5.3.1 Installation Rules for Host Interfaces This section explains the installation rules for host interfaces.
To avoid this, allow the packed host interface sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new temperature. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 82
• Do not put anything on the host interface. • Do not knock or drop the host interface on hard objects. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
The value shows the time required for volume formatting when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
The value shows the copyback process time when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
If a possible error that may occur is detected or an error occurs when remote support service is used, the contents of events are automatically sent to the remote support center and notified to the user. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Has there been a recent main power failure? If the Power Resume function is enabled, the ETERNUS DX Disk storage system turns on automatically after the power is restored. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 87
2 Connect the QSFP cable while the drive enclosure is on. 3 Press the controller enclosure’s Power switch to turn on the ETERNUS DX Disk storage system. End of procedure ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 88
In the details screen for each component, check the detailed information for each component with a and contact your maintenance engineer. When checking the general status via ETERNUS CLI, refer to "ETERNUS CLI User’s Guide". ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 89
IMPORTANT for all of the LAN ports are initialized after the following procedure is per- formed. Procedure Remove the flange cover of the controller enclosure. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 90
• To use the SNMP Manager, enable the SNMP connection. If not, the ETERNUS DX Disk storage system does not respond to SNMP access. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 91
When rebuild, copyback, or redundant copy is being performed in a RAID group with a "High" rebuild priority, the performance may be reduced until the operation is complete. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
Page 92
Check if an error occurs in a path by using a path management tool such as ETERNUS Multipath Manager. Refer to the relevant manuals and take the required actions. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED...
Disk storage system, obtain the required log/dump information using the log/dump collection function of ETERNUS Web GUI. Refer to "ETERNUS Web GUI User’s Guide" for how to obtain this information. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 95
The year is display with four digits. The detailed information of the event is displayed. For multiple process results, each process result is displayed on a separate line. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
6: Informational For the "RFC3164" format, the HEADER part follows the PRI part. For the "RFC5424" format, "1" and then a blank follow the PRI part. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 97
ETERNUS DX Disk storage system is output in the following format: xxx.xxx.xxx.xxx The IPv4 address is output based on the "IETF STD13, RFC 1035" specification. A blank follows this item. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 98
For multiple process results, each process result is enclosed by brackets. Refer to "A.2 Message List" (page 104) for details. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Trap No. 5 returns to normal status. fjdarye100SensorStatusChangeToNormal This Trap is sent to notify that an event notified by Trap No. 6 returns to normal status. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 100
[2]:snmpTrapOID coldStart The operation time of 1.3.6.1.6.3.1.1.5.1 the SNMP Agent (centiseconds) The operation time is authenticationFailure 1.3.6.1.6.3.1.1.5.5 reset when the SNMP Agent starts or restarts. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 101
TRAP No. Information [3]:fjdaryTrapMessage Information [4]:fjdaryTrapWarningInfo 26 fjdarye100 Notification of Information [1]:fjdaryTrapItemId SensorStatus alarm cancel Information [2]:fjdarySspMachineId ChangeTo for TRAP No. Information Normal [3]:fjdaryTrapSensorInfo Information [4]:fjdaryTrapMessage ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 102
Information [3]:fjdaryTrapMessage Information [4]:fjdaryTrapWarningInfo 26 fjdarye100 Notification of 1.3.6.1.4.1.211.4.1.1. Information [1]:fjdaryTrapItemId SensorStatus alarm cancel for 126.1.100.0.26 Information [2]:fjdarySspMachineId ChangeToNormal TRAP No. 6 Information [3]:fjdaryTrapSensorInfo Information [4]:fjdaryTrapMessage ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
ETERNUS Web GUI or ETERNUS CLI. For details on the sense code that is notified to the server, refer to "A.2.6 Sense Codes" (page 138). ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Meaning Hot spares Thin Provisioning Volume(s) Thin Provisioning Pool SMART Self-Monitoring Analysis and Reporting Technology Firmware Hard Disk Drive Solid State Drive Direct Memory Access ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 106
CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) v: EXP number (0) p: Port number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 107
MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 108
CA type m: CM number (0 – 1) P: Port number (0 – 1) pp...: Component number ss...: Serial number rr...: Version oo...: Additional information ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 109
CM number (0 – 1) tion setting. They zz: Model name (DX80S2 or DX90S2) are not notified pp...: Component number during mainte- ss...: Serial number nance operations. rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 110
CM number (0 – 1) are not notified zz: Model name (DX80S2 or DX90S2) during mainte- pp...: Component number nance operations. ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 111
Disk speed cc...: Disk information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 112
Disk speed cc...: Disk information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 113
Drive capacity (GB/TB) cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 114
Disk speed cc...: Disk information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 115
Drive capacity (GB/TB) cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 116
SS: Component subtype for Error Severity uu: DE-ID ("00" for a controller enclosure) Level in the event notification setting. They are not notified dur- ing maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 117
REC Buffer Halt (Path Error) • REC Buffer Halt (Overload) • REC Buffer Halt (Other Error) These mes- sages are not notified during maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 118
Rebuild to the hot spare is halted. the event notifi- xxx: RAID group number (hexadecimal) cation setting. They are not noti- fied during main- tenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 119
Copyback to the replaced drive is complete. Severity Level in xxx: RAID group number (hexadecimal) the event notifi- cation setting. They are not noti- fied during main- tenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 120
RAID group number (hexadecimal) data" is enabled for Error Severity Level in the event notification setting. They are not notified dur- ing maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 121
Memory capacities are smaller than the minimum value in multiple CMs. M E2070015 E2070015 NOT READY(21:Auto CFD) The device is in Not Ready status. Automatic CFD is performed. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 122
FTRP number (hexadecimal) M E8090xxx E8090xxx FTRP#xxx was all allocated There is no more available capacity in the Flexible Tier Pool. xxx: FTRP number (hexadecimal) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 124
Port number (0 – 1) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 125
S: CA slot number (0 – 1) V: Device number (0 – 1) zz: CA type m: CM number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 126
CE intake temperature error (Warning) is Warning Level detected. in the event notification setting. They are not notified during mainte- nance opera- tions. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 127
Disk speed cc...: Disk information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 128
Disk speed cc...: Disk information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 129
Drive capacity (GB/TB) cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 130
Drive capacity (GB/TB) cc...: Drive information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version tt...: Data code qq: Configuration code ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 131
MM: CM module ID (10 – 11) m: CM number (0 – 1) zz: Model name (DX80S2 or DX90S2) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 132
PSU error is detected. SS: Component subtype uu: DE-ID ("00" for a controller enclosure) n: PSU number (0 – 1) pp...: Component number ss...: Serial number rr...: Version ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Snap Data Pool (encrypted) usage rate exceeds the threshold (Level1) $a% and reaches $b%. $a: Threshold of Snap Data Pool $b: Usage rate of Snap Data Pool ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 134
The trial license (local copy) has expired I 00000016 The trial license(Remote Copy) has expired. Detail information is not displayed. The trial license (remote copy) has expired. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 135
&b: Slot number &c: Type (Global or Dedicated) &d: RAID group number (only for Dedicated Hot Spares) &e: RAID group name (only for Dedicated Hot Spares) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 136
Device shutdown has started. setting. I 01050030 Controller firmware updated ($a) Detail information is not displayed. Controller firmware version is updated. $a: VxxLxx-xxxx (Firmware version) ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 137
CE or DE. tion setting. This row indicates TrapWarningInfo for Trap No. 25 and TrapSensorInfo for Trap No. 26. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
CA SFP+ is disconnected. CA SFP+ is disconnected. CA SFP is disconnected due to an SFP type that cannot be recognized. CM QSFP is disconnected. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 139
"Remote Path Error" is enabled for CA is rebooted. Warning Level in the event notification IOM is rebooted. setting. They are not notified during mainte- nance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 140
This sense code is notified when "Rebuild/Copyback w/o redundant" is enabled for Error Severity Level in the event notification setting. This is not notified during maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 141
Level in the event notification set- DE QSFP port error is detected. ting. They are not notified during mainte- PSU error is detected. nance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 142
"Temperature Warning" is enabled for DE intake temperature error is detected. Warning Level in the event notification setting. They are not notified during maintenance operations. ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation- Copyright 2012 FUJITSU LIMITED P3AM-4842-03ENZ0...
Page 143
• Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. •...