Air" I Nhot W Ater F Aucets; Rumbling N Oise; High Temperature Shut O Ffsystem; Notenough O Rnohot W Ater - Kenmore 153.313340 Owner's Manual

Potable water heating only not suitable for space heating
Hide thumbs Also See for 153.313340:
Table of Contents

Advertisement

If thesmelly w ater p ersists aftertheanode replacement
and
chlorination treatment, wecanonlysuggest thatcontinuous
chlorination
andfiltering c onditioning
equipment beconsidered
toeliminate thewater p roblem.
Donotremove t heanode leaving thetankunprotected. By
doing so,aH warranty o nthewater h eater i svoided.
"AmR" INHOT W ATER FAUCETS
Explosion
Hazard
" FlammaMe
hydrogen
gases
may be present
" Keep all ignition sources away
from faucet when turning on hot
water,
HYDROGEN
GAS:
Hydrogen
gas can be produced
in a hot
water
system
that has not been
used for a long period
of time
(generally
two weeks
or more).
Hydrogen
gas
is extremely
flammable
and explosive.
To prevent
the possibility
of injury
under
these
conditions,
we recommend
the hot water
faucet
be opened
for several
minutes
at the kitchen
sink before
any
electrical
appliances
which
are connected
to the hot water
system
are used
(such as a dishwasher
or washing
machine).
If hydrogen
gas is present,
there
will probably
be an unusual
sound
similar
to air escaping
through
the pipe as the hot water
faucet
is opened.
There
must
be no smoking
or open
flame
near the faucet
at the time it is open.
RUMBUNG
NOISE
Before
removing
any
access
els or servicing
the water
heater, make sure the electrical
supply
to the water
heater
is
ed "OFF'"
Fai!ure to do this could resu!t in
death,
serious
bodily
iniury, or
)erty damage.
HAZARD
OF ELECTRICAL
SHOCK!
Before
removing
any
access
panels
or servicing
the water
heater,
make
sure
the
electrical
supply
to the water
heater
is turned
'OFF'L
Failure
to
do this could
result in DEATH,
SERIOUS
BODILY" INJURY,
OR
PROPERTY
DAMAGE.
Remove
the two
screws
securing
the access
panel
and
remove
pane!.
Remove
the insulation
block.
Reset the high limit by pushing in the red button marked
'RESET",
RESET
--BUTTON
In some
water
areas,
scale
or mineral
deposits
will build
up
on your
heating
elements.
This buildup
will cause
a rumbling
noise.
Follow
'Element
Cleaning/Replacement"
instructions
to clean
and replace
the elements.
HiGH TEMPERATURE
SHUT OFF SYSTEM
The water
heater
has a high limit shut off system
with a reset
button
located
on the thermostat.
Follow
the resetting
instructions
which
refer
to the high
limit
behind
the access
panel.
* Before
beginning,
turn "OFF"
electrical
power
supply
to the
water
heater.
21
• Replace
the insulation
block
so that it completely
covers
the
thermostat
and element.
• Replace
the access
panel.
• Turn 'ON"
electric
power
to the water
heater.
If the high limit must be reset again,
cal! Sears
Service
Center
to find out why the high limit turned
'OFF"
the electric
power.
NOT ENOUGH
OR NO HOT WATER
• In a new installation,
the water
heater
may not be properly
connected.
Make
sure
the cold water
supply
valve
is open.
Review
and check
piping
installation.
Make
sure
that the
cold water
line is connected
to the cold
water
inlet
to the
water
heater
and the hot water
line to the hot water
outlet
on
the water
heater.
• Make sure the electrical
supply
to your water
heater
is "ON".
• Check
for loose
or blown
fuses
in your
water
heater
circuit.
Circuit
breakers
weaken
with
age and may not handle
their
rated
load and should
be replaced.