T &Pvalve Andpipe Insulation; Temperatureopressure Relief V Alve - Kenmore 153.313340 Owner's Manual

Potable water heating only not suitable for space heating
Hide thumbs Also See for 153.313340:
Table of Contents

Advertisement

meter witha check v alve, e tc. i nthecold water s upply; means
shall b eprovided to control thermal expansion. Contact the
local u tilityor Sears Service Center o nhowto control this
situation.
NOTE: Ifusing c opper tubing, solder tubing t oanadapter before
attaching theadapter tothecoldwater i nletconnections.
Do
notsolder t hecold water s upply l inedirectly t othecold water
inlet. I twillharm thediptube anddamage thetank.
* Look at the top cover of the water
heater. The hot water outlet
is marked
'HOT".
Put two or three turns of teflon tape around
the threaded
end of the threaded-to-sweat
coup%g
and
around
both ends
of the 3/4" threaded
nipple.
Using
flexible
connectors,
connect
the hot water
pipe to the hot water
outlet
of the water
heater.
. Look at the top cover of the water heater.
The cold water
inlet
is marked
"COLD".
Put two or three turns of teflon tape around
the threaded
end of the threaded-to-sweat
coupling
and
around
both ends
of the 3/4" threaded
nipple.
Using
flexible
connectors,
connect
the cold
water
pipe to the cold
water
inlet of the water
heater.
NOTE:
Your water
heater
is insulated
to minimize
heat
loss
from
the
tank.
Further
reduction
in
heat
loss
can
be
accomplished
by insulating
the
hot water
lines
from
the
water
heater.
Installation
Completed
Using Installation
Kit
NOT OUTLET
TO HOUSE
THREADED
TO SWEAT
COUPLING
t
THREADED
TO SWEAT
COUPLING
SHUT=OFF
VALVE
COLD
INLET
WATER
UNE
$f4"
3/4"
DmSCNARGE P_PE
IgO NOT CAP OR PLUG)
PRESSURE
T & P Valve and Pipe Insulation
Remove insulation for T & P valve and pipe connections from
carton.
Fit pipe insulation
over the incoming
cold water
line and the hot
water
line.
Make
sure
that
the insulation
is against
the top
cover
of the heater.
Fit T & P valve insulation
over valve. Make sure that the insulation
does
not interfere
with the lever of the T & P valve.
Secure
al! insulation
using tape.
PiPE
INSULATION
Temperature-Pressure
Relief Valve
11
Expmosion
Hazard
Tern perature-pressure
relid valve
must comply with ANSI Z2122
and ASM E code.
Properly sized temperature4eiief
valve must be installed in opening
provided,
• Can
result
in overheating
and
excessive tank pressure
Can cause serious injury or death.
At the time of manufacture
this water
heater
was provided
with
a combination
temperature-pressures
relief
valve
certified
by
a nationally
recognized
testing
laboratory
that
maintains
periodic
inspection
of production
of listed
equipment
or
materials,
as meeting
the requirements
for Relief
Valves
and
Automatic
Gas Shut-off
Devices
for Hot Water
Supply
Systems,
and the current
edition
of ANSI
Z21.22
• CSA 4.4 and the code
requirements
of ASME.
If replaced,
the valve
must
meet
the
requirements
of local
codes,
but not less than
a combination
temperature
and pressure
relief valve
certified
as meeting
the
requirements
for Relief
Valves
and Automatic
Gas
Shut-off
Devices
for Hot Water
Supply
Systems,
ANSI Z21.22.
CSA 4.4
by a nationally
recognized
testing
laboratory
that
maintains
periodic
inspection
of production
of listed
equipment
or
materials.
The valve
must be marked
with a maximum
set pressure
not to
exceed
the marked
hydrostatic
working
pressure
of the water

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.313640153.313242153.313140153.313442Economizer 6

Table of Contents