Wiring Diagram; Wiring - Kenmore 153.313340 Owner's Manual

Potable water heating only not suitable for space heating
Hide thumbs Also See for 153.313340:
Table of Contents

Advertisement

NOTE: The coldwater s upply valve must b e[eftopen when
thewater h eater i s inuse.
• To insure
complete
fi!ling
of the tank,
allow
air to exit
by
opening
the nearest
hot water
faucet.
Allow water to run until
a constant
flow
is obtained.
This will let air out of the water
heater
and the piping.
• Check
al! new water
piping
for leaks.
Repair
as needed.
You
must
provide
al! wiring
of the proper
size outside
of the
water
heater.
You must obey local codes
and electric
company
requirements
when
you
install
this wiring.
If you are not familiar
with electric
codes
and practices,
or if you
have any doubt, even the slightest
doubt,
in your ability to connect
the wiring to this water
heater, obtain the service
of a competent
electrician.
Contact
your
Sears
salesperson
to arrange
for a
professional
electrician.
Wiring
Diagram
STANDARD
WIRING
FOR 2 WmRE LEAD WATER HEATERS
240 VOLT SINGLE
ELEMENT
<,
m
C
BLACK
TO ELECTRIC
POWER SUPPLY
1
4
2
4
w
22A2T'VAC
12_V_
PrDY I2048OVAC
Fire Hazard
and
Electric
Shock
Hazard
Do not use this water heater with any
voltage other than shown on the model
rating plate.
Failure to use the correct voltage shown
on the model rating plate could result in
death, serious bodily injury, or property
damage.
WATER
HEATERS
EQUIPPED
FOR ONE VOLTAGE
ONLY: This
water
heater
is equipped
for one type voltage
only. Check
the
rating plate near the bottom
access
panel for the correct
voltage.
DO NOT use this water
heater
with any voltage
other than the
one shown
on the model
rating
plate.
Failure
to use the correct
voltage
can
cause
problems
which
can
result
in DEATH,
SERIOUS
BODILY
INJURY,
OR PROPERTY
DAMAGE.
If you
have any questions
or doubts
consult
your
electric
company.
If wiring
from your fuse box or circuit
breaker
box was aluminum
for your old water heater,
replace
it with copper
wire. If you wish
to reuse
the existing
aluminum
wire,
have
the connection
at
the water
heater made by a competent
electrician.
Contact
your
Sears
salesperson
to arrange
for a professional
electrician.
Provide
a way
to easily
shut
off the electric
power
when
working
on the water
heater.
This
could
be with
a circuit
breaker
or fuse
block
in the entrance
box
or a separate
disconnect
switch.
Wiring
Property
Damage
Hazard
Improper
installation
and use may
result in
property damage.
Fi!l tank with water before operating.
2_
Install
and connect
a circuit
directly
from the main fuse
or
circuit
breaker
box. This
circuit
must
be the right
size
and
have its own fuse or circuit
breaker.
Refer to the chart
in the
'Product
Specifications"
section
for the correct
size wire and
fuse
or circuit
breaker.
Never use this water
heater
unless
it is completely
full of water.
To prevent
damage
to the tank and heating
element,
the tank
must
be filled
with water.
Water
must flow
from the hot water
faucet
before
turning
"ON"
power.
13
3. If metal
conduit
is used for the grounding
conductor:
The grounding
electrode
conductor
shall be of copper,
aluminum,
or copperclad
aluminum.
The
material
shall
be of one continuous
length
without
a splice
or
joint.
B,
Rigid
metal
conduit,
intermediate
metal
conduit,
or
electrical
metallic
tubing
may be used for the grounding
means
if conduit
or tubing
is terminated
in fittings
approved
for grounding.
C.
Flexible
metal
conduit
or flexible
metallic
tubing
shall

Advertisement