Troubleshooting
Trouble
Probable
Cause
Remedy
Red power light and digital display
. No Power.
. Check 120 volt power source.
not illuminated,
. Power button has not been
. Press power button once to turn
depressed,
on,
Fan not operating
(Red power light
. ROOM humidity
level is not 3% or
, Raise SET humidity level if
and digital display is illuminated),
more below SET humidity
level,
desired,
Fan running continuously,
. SET humidity level is 65%,
. A SET humidity percentage
of
65% operates fan continuously,
Adjust SET level between 25% -
60%.
. ROOM humidity
level has not
, Continue to run until desired
reached
1% or more above SET
humidity level is achieved.
This
humidity level,
may take up to 48 hours initially,
Poor evaporation
of water,
. CK FILTER message flashing,
' Change to a fresh new filten
. NOTE: Local water varies from
are to area and under certain
conditions mineral will build up
more rapidly in the filter,
Bottle empties completely.
. This is normal for initial filling,
. Refill bottle for maxim[_m run time,
Bottle contim_es to empty
. Air is entering water bottle,
, Ensure fill cap is tight with no
after complete filling,
interfering debris.
, Check for leak in water bottle,
Bottle not emptying,
. Base full of water,
. The base will hold the contents of
water bottle (7.2 litres). Continue
to run humidifier to deplete water
from base,
CK FILTER message does not
. A loss of power has caused the
, Replace filter
appear even when filter is dirty or
CK FILTER message to
humidifier
performance
is clearly
prematurely
reset,
reduced,
Fan operating slower than speed
. Humidifier
is in DRY OUT mode,
. Humidifier automatically
switches
registered
on digital display,
fan speed to WHISPER
when
DRY OUT mode message
is
displayed.
Humidifier
not shutting off during
. Filter not dry,
. During DRY OUT mode the
DRY OUT mode,
humidifier will continue to run on
WHISPER speed as required for a
2 hour period,