Craftsman 351.227240 Operator's Manual page 8

6 1/8" jointer/planer

Advertisement

WARNING:
Any receptacle replacement s_uid be
_
performed by a qualified electrician.
A temporary 3-prong to 2-prong groundingadapter (see
Figure 15) is available for connecting plugs to a two
pole outlet if it _s-properly grounded.
GroundingLug
Make Sure This
Is Connected
3-Prong
To A Known
Ground
Hertz..
i....:.:....
_:,i...
.....
....
!..
:,._60
Phase .......
.........................
Single
RPM ..................................
5000
ELECTRICAL CONNECTIONS
WARNING:
Make sure unit is turned off and discon-
nected from power source before inspecting any wiring.
The unit is wired as illustrated in the wiring schematic
(see Figure 16).
2-Prong Receptacle
Rgure 15 - 2-Prong Receptacle with Adapter
Do not use a 3-prong to 2-prong grounding adapter
unless permitted by local and national codes and
---
Ordinances. (A 3-prong to 2-prong grounding adapter
is not permitted in Canada.)
Where a 3-prong to 2-prong grounding adapter is
permitted, the rigid green tab or terminal on the side
of the adapter must be securely connected to a
permanent electrical ground such as a properly
grounded water pipe, a properly grounded outlet box
or a properly grounded wire system.
Many cover plate screws, water pipes and outlet
boxes are not properly grounded. To ensure proper
ground, grounding means must be tested by a quali-
fied electrician.
EXTENSION
CORDS
• The use of any extension cord will cause some drop
in voltage and loss of power.
• Wires of the extension cord must be of sufficient size
to carry the current and maintain adequate voltage.
Use the table to determine the minimum wire size
(A.W.G.) extension cord.
Use only 3-wire extension cords having 3-prong
grounding type plugs and 3-pole receptacles which
accept the tool plug.
If the extension cord is worn, cut or damaged in any
way, replace it immediately.
EXTENSION CORD LENGTH
Wire Size
A.W.G.
Upto 50 ft................................
16
50-100 ft ..................................
14
NOTE: Using extension cords over 100 ft. long is not
recommended.
.-.-
MOTOR
Jointer/planer is supplied with a 2 HP (max developed)
motor.
The 120 Volt AC universal motor has the:following
specifications:
Horsepower (Maximum Developed) ..............
2
Voltage ....
: ............................
120
_e
re_.. ..............................
10.8
]31 ° ]28
Wire
Nut
Figure 16 ' Wiring Schematic I
I
The motor is assembled with an approved three con-
ductor cord to be used on 120 volts as indicated. The
power supply to the motor is controlled by a double
pole locking rocker switch.
Remove the key to prevent unauthorized use.
The power lines are inserted directly onto the switch.
The green ground line must remain securely fastened
to the frame to propedy protect against electrical shock.
8
DESCRIPTION
Craftsman 6 %" jointer/planer is used to surface the
faces and edges of boards, produce a fiat surface on
warped boards and shape rabbets, bevels, chamfers
and tapers. The jointer/planer features heavy cast iron
infeed and outfeed tables with precision ground work
surfaces and leadscrews for precise table height adjust-
ment. Rigid, center mount guide fence is provided with
bevel stops at 90 ° (from bed) and 45 ° .Tool comes with
locking rocker switch with removable key and push
blocks. Jointer/planer easily handles rough-cut lumber,
planes hard and soft woods up to 6 %" wide using a
three knife cutterhead, and takes cuts up to l/s",and up
to 1/=,rabbets.
OPERATION
SAFETY
RULES
Jointing is a surfacing operation in which a small
amount of wood is removed from the edges and faces of
boards to get smooth, straight and even surfaces such
that the two edges that run across the planing blocks
would fit together perfectly, forming a seamless joint.