Mode button
Up/Down buttons
Reset opening
Description
The RLV430 thermostat can be used to control an electric heating
system such as a baseboard heater, a radiant floor, a radiant ceiling,
a convector or a fan-forced heater.
The thermostat cannot be used with the following:
a resistive load under 2 A
a resistive load over 14.6 A
systems driven by a contactor or a relay (inductive load)
central heating systems
SUPPLIED PARTS
One (1) thermostat
Two (2) 6-32 mounting screws
Two (2) solderless connectors

Installation

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
All cables and connections must comply with local electrical
codes.
This thermostat has tinned copper wires for line and load con-
nections. Special CO/ALR solderless connectors must be used if
these wires will be connected to aluminium conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing
the heater.
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.
RLV430
Day button
Hour button
Minute button
Program button
Return button
1.
2.
Time and day
Appears if the
thermostat is configured
for a fan-forced heater
Appears when the
setpoint is displayed
Heating power
indicator
Period no. in
Automatic mode
Automatic
mode
1) Connect the thermostat
Connect the thermostat wires to the power and to the load using
solderless connectors for copper wires.
2-wire installation
4-wire installation
RLV430

User Guide

Programmable Thermostat
Flashes when the
clock has been reset
Temperature
Appears during
a power failure
Setting no. in
Economy mode
Economy
Manual
mode
mode
69-1855-1
2008-01-29
1/4

Advertisement

loading

Summary of Contents for Honeywell RLV430A

  • Page 1: Installation

    RLV430 User Guide Programmable Thermostat Time and day Appears if the Day button thermostat is configured for a fan-forced heater Hour button Flashes when the Appears when the Minute button clock has been reset setpoint is displayed Program button Temperature Return button Heating power indicator...
  • Page 2: Temperature Display And Setting

    2) Mount the thermostat Time display Push the excess wires back To switch between the 12-hour format and the 24-hour format: inside the electrical box. Open the thermostat’s door. Secure the thermostat to the Press and hold the Hour button. electrical box using the provided screws.
  • Page 3: Thermostat Reset

    The thermostat is preprogrammed with the following schedule: The economy mode has two periods which should be set as follows: Period Monday to Friday Saturday & Sunday Period Temperature Setting Start Time Setting Start Time Temperature Start Time Temperature Set the day and time that you Wake 6:00 21°C (70°F)
  • Page 4: Troubleshooting

    This warranty does not cover removal or reinstallation costs. This above a heat source such as a warranty shall not apply if it is shown by Honeywell that the defect or light dimmer. malfunction was caused by damage which occurred while the prod-...

This manual is also suitable for:

Rlv430