WAVE-574 Hardware Specifications
Table A-1
WAVE-574 Features and Specifications (continued)
Specification
2
Acoustic noise
Environment
1. The limits apply when operated in an ambient environment temperature of +23.0°C ± 2° (+73.4°F ± 2°).
OL-17738-01
Description
Idle:
L
–6.30 B
WAd
L
–52.07 dB
pAm
Operating:
L
–6.38 B
WAd
L
–52.77 dB
pAm
Air temperature:
3
Operating
: 10 to 35 °C (50 to 95 °F)
Non-operating: –30 to 60 °C (–22 to 140 °F)
Maximum rate of temperature change:
4, 5
Operating
: 10 °C/hr (18 °F/hr)
Non-operating: 20 °C/hr (36 °F/hr)
Humidity:
Operating: 10% to 90%
Nonoperating: 5% to 95%
Maximum wet bulb temperature (noncondensing):
Operating: 28 °C (82.4 °F)
Nonoperating: 38.7 °C (101.7 °F)
Altitude:
Operating: 3,050 m (10,000 ft)
Nonoperating: 9144 m (30,000 ft)
Maximum rate of altitude change:
Operating: 457 m/min (1,500 ft/min)
Nonoperating: 457 m/min (1,500 ft/min)