Troubleshooting the System Hardware
Advanced Memory Protection mode: RAID memory with Advanced ECC
...Xxxx MB System memory and xxxx MB memory reserved for RAID.
An Unexpected Shutdown occurred prior to this power-up
Critical Error Occurred Prior to this Power-Up
Fan Solution Not Fully Redundant
Fan Solution Not Sufficient
Fatal DMA Error
OL-17738-01
Possible Cause: This message indicates RAID Memory is enabled and indicates
the amount of memory reserved for this feature.
Action: None.
Possible Cause: The WAVE appliance shut down because of an unexpected event
on the previous boot.
Action: Check the System Management Log or OS Event Log for details on the
failure.
Possible Cause: A catastrophic system error, which caused the WAVE appliance
to crash, has been logged.
Action: If the problem persists, contact the Cisco Technical Assistance Center.
Possible Cause: The minimum number of required fans is installed, but some
redundant fans are missing or failed.
Action: If the problem persists, contact the Cisco Technical Assistance Center.
Possible Cause: The minimum number of required fans is missing or failed.
Action: If the problem persists, contact the Cisco Technical Assistance Center.
Possible Cause: The DMA controller has experienced a critical error that has
caused an NMI.
Action: If the problem persists, contact the Cisco Technical Assistance Center.