CSCsq66823
Symptom: On an MDS 9222i switch, an upgrade from SAN-OS Release 3.2(x), Release 3.3(1), or
Release 3.3(1a) to SAN-OS Release 3.3(1c) fails when there is an active FC-Redirect configuration
(created by SME or DMM applications) on the switch. An active FC-Redirect configuration is
defined as:
If an upgrade is attempted when an active configurations is present, the switch will go into a
disruptive upgrade.
Workaround: This issue is resolved.
CSCsq69543
Symptom: Fabric Manager does not update PortChannel operation state changes in 5 minutes.
Workaround: This issue is resolved.
CSCsq78481
Symptom: During an upgrade, the standby Supervisor module fails.
Workaround: This issue is resolved.
CSCsr08325
Symptom: Fabric Manager Web Client shows fabric events with the following description:
VSAN ... zone activation success, local switch is 00:00:00:00:00:00:00:00
The switch sends the enhanced zone activation traps with switch WWN of 00:00:00:00:00:00:00:00.
This occurs the enhanced zone mode is configured for a VSAN.
Workaround: This issue is resolved.
CSCsr18556
Symptom: License records are not removed when a fabric is purged from the database. License
information may be incorrect if the same fabric is added back to Fabric Manager at a later time.
Workaround: This issue is resolved.
CSCsr15094
Symptom: After issuing the show sme internal event-history all command, some ITLs display the
following message:
20) FSM:<LUN=0x16> Transition at 686497 usecs after Wed Jul 2 12:00:57 2008
Previous state: [SME_CPP_TAPE_DRV_WAIT_CPP_SUP_GET_CRYPTO_KEYS]
Triggered event: [SME_CPP_TAPE_DRV_EV_SUCCESS]
Next state: [SME_CPP_TAPE_DRV_WAIT_CPP_DPP_VERIFY_CTH]
Curr state: [SME_CPP_TAPE_DRV_WAIT_CPP_DPP_VERIFY_CTH]
If the KMC response comes back with a failure after 10 seconds, it might stop in the CTH state.
Workaround: This issue is resolved.
CSCsr18847
Symptom: Port manager failed when issuing the show run command.
Workaround: This issue is resolved.