If youarenotfamiliar withelectric c odes andpractices, or if
youhave anydoubt, even theslightest doubt, inyourability to
connect thewiring tothiswater h eater, obtain theservice o fa
competent electrician. Contact y ourSearssalesperson to
arrange f ora professional
electrician.
WATER H EATERS EQUIPPED FORONE VOLTAGE ONLY:
This water h eater i sequipped forone type voltage o nly. C heck
therating platenear t hebottom access p anel forthecorrect
voltage. DONOT usethis water h eater withanyvoltage o ther
thantheoneshown o nthemodel rating plate. F ailure t ouse
thecorrect voltage cancause problems which canresult i n
DEATH, S ERIOUS BODILY INJURY, O R PROPERTY
DAMAGE. If youhave anyquestions ordoubts c onsult your
electric c ompany.
Ifwiring f rom your f use boxorcircuit breaker box was aluminum
foryouroldwaterheater, replace it withcopper wire.If you
wish toreuse theexisting a luminum w ire, h ave theconnection
atthewater h eater m ade bya competent electrician. Contact
your S ears s alesperson
toarrange foraprofessional
electrician.
1.Provide a wayto easily shutofftheelectric p ower w hen
working onthewaterheater. Thiscould bewitha circuit
breaker or fuseblock in theentrance b oxor a separate
disconnect switch.
2. Install andconnect a circuit d irectly f rom themain fuseor
circuit b reaker box. T hiscircuit m ust b etheright s izeand
have itsown fuse orcircuit breaker. Refer tothechart i nthe
"Product Specifications"
section forthecorrect size wire and
fuseorcircuit breaker.
3. If metal conduit is used for the grounding conductor:
A.
The grounding
electrode
conductor
shall be of copper,
aluminum,
or copperclad
aluminum.
The
material
shall
be of one continuous
length
without
a splice
or
joint.
S.
Rigid
metal
conduit,
intermediate
metal
conduit,
or
electrical
metallic
tubing may be used for the grounding
means
if conduit
or tubing
is terminated
in fittings
approved
for grounding.
C.
Flexible
metal
conduit
or flexible
metallic
tubing
shall
be permitted
for
grounding
if all
the
following
conditions
are met:
The length
in any ground
return
path does
not exceed
6 feet.
The circuit
conductors
contained
therein
are protected
by overcurrent
devices
rated at 20 amperes
or less.
The conduit
or tubing
is terminated
in fittings
approved
for grounding.
For complete
grounding
details
and all allowable
exceptions,
refer to the current
edition
of the NEC - National
Electrical
Code
NFPA 70.
4. A standard
1/2" conduit
opening
has been
made in the water
heater junction
box for the conduit
connection.
5. Wiring
Diagrams,
(see "Wiring Diagrams'section)
have been
supplied
showing
the two most common
types of connections
between
the water
heater
and the power
supply.
You can
easily
see which
type connection
you have by removing
the
junction
box cover
on top of the water
heater.
Two Wire
Connection
Diagram:
is the most common
requiring
you to simply
connect
red to red,
black
to
black,
and
the
ground
wire
to the
green
ground
screw
in the junction
box of the water
heater.
Three
Wire
Connection
Diagram:
is used when you
are
connecting
the water
heater
to a power
supply
that has a "Time
Clock"
or "Off Peak"
meter.
To make
these
connections
refer to block
1 or 2 in this wiring
diagram
for the type of system
you have.
NOTE:
If you have purchased
a three wire connection
water
heater but you are not on a "Time Clock"
or "Off Peak"
meter
and
have
a standard
two wire
connection
power
supply,
simply
follow
the connection
diagram
in block 3 of the three
wire connection
diagram.
6. Use wire nuts and connect
the power
supply
wiring
to the
wires
inside
the water
heater's
junction
box.
The
water
heater
must
be electrically
"grounded"
by the
installer.
A green
ground
screw
has been
provided
on the
water
heater's
junction
box.
Connect
ground
wire
to this
location.
8. Replace
the wiring
junction
cover
using the screw
provided.
CONDUIT
WIRE NUT
GREEN
GROUND
SCREW
FIGURE 23.