Wiring - Kenmore 153.586320 Use & Care Manual

Electric
Hide thumbs Also See for 153.586320:
Table of Contents

Advertisement

Wiring
You must provide all wiring of the proper size outside of the
water heater. You must obey local codes and electric company
requirements when you install this wiring.
If you are not familiar with electric codes and practices, or if you
have any doubt, even the slightest doubt, in your ability to connect
the wiring to this water heater, obtain the service of a competent
electrician.
Contact your Sears salesperson
to arrange for a
professional electrician.
WATER HEATERS EQUIPPED
FOR ONE VOLTAGE ONLY:
This water heater is equipped for one type voltage only. Check
the rating plate near the bottom access panel for the correct
voltage. DO NOT use this water heater with any voltage other
than the one shown on the model rating plate. Failure to use the
correct voltage can cause problems which can result in DEATH,
SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you
have any questions or doubts consult your electric company.
Fire Hazard / Electric
Shock Hazard
Do not use this water heater with
any voltage other than shown on the
model rating plate.
Failure to use the correct voltage
shown
on the model rating plate
could result in death, serious bodily
injury, or property damage.
The length
in any ground
return
path
does
not
exceed 6 feet (1.82 m).
The circuit conductors contained therein are protected
by overcurrent devices rated at 20 amperes or less.
The conduit or tubing is terminated in fittings approved
for grounding.
For complete grounding
details and all allowable exceptions,
refer to the current edition of the NEC- National Electrical Code
NFPA 70.
4. Astandard
112" conduit opening has been made in the water
heater junction box for the conduit connection.
5. Awiring diagram (Figure 24) has been provided to show the
connections between the water heater and the power supply.
Two Wire Connection Diagrams: is the most common
requiring you to simply connect red to red, black to
black, and the ground wire to the green ground screw
in the junction box of the water heater.
6. Use wire nuts and connect the power supply wiring to the
wires inside the water heater's junction box.
7. The water heater must be electrically
"grounded"
by the
installer. A green ground screw has been provided on the
water heater's junction
box. Connect ground wire to this
location.
8. Replace the wiring junction cover using the screw provided
_-_
I_UNCTION
BOX COVER
FROM HOME
ELECTRICALSERVICE
BLACKWIRE_
<
If wiring from your fuse box or circuit breaker box was aluminum
for your old water heater, replace it with copper wire. If you wish
to reuse the existing aluminum wire, have the connection at the
water heater made by a competent
electrician.
Contact your
Sears salesperson to arrange for a professional electrician.
1. Provide a way to easily shut off the electric power when
working on the water heater. This could be with a circuit
breaker or fuse block in the entrance
box or a separate
disconnect switch.
2. Install and connect a circuit directly from the main fuse or
circuit breaker box. This circuit must be the right size and
have its own fuse or circuit breaker. Refer to the chart in the
Product Specifications
section for the correct size wire and
fuse or circuit breaker.
3. If metal conduit is used for the grounding conductor:
a.
The grounding electrode conductor shall be of copper,
aluminum,
or copperctad
aluminum.
The material
shall be of one continuous length without a splice or
joint.
b.
Rigid metal conduit,
intermediate
metal conduit, or
electrical metallic tubing may be used for the grounding
means if conduit or tubing is terminated
in fittings
approved for grounding.
c.
Flexible
metal
conduit
or flexible
metallic
tubing
shall be permitted
for grounding
if all the following
conditions are met:
(GROUND
SCREW IS
UNDER
THE COVER)
1/2" CONDUIT
CONNECTION
..... <j Z_
FIGURE 11.
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.586410153.586310153.586400153.586500153.586510

Table of Contents