Filling The Water Heater; Converting The Lower Element - Kenmore 32626 - Power Miser 6 Owner's Manual

Electric water heater
Table of Contents

Advertisement

Filling
the Water Heater
Property
Damage
Hazard
• Avoid water heater
damage.
• Fill tank with water
before operating.
Never
use this water
heater
unless
it is completely
full of water•
To prevent
damage
to the tank and heating
element,
the tank
must
be filled
with water.
Water
must flow
from the hot water
faucet
before
turning
"ON"
power•
To fill the water
heater
with water:
1. Close
the water
heater
drain valve
by turning
the handle
to
the right (clockwise).
The drain valve
is located
on the lower
front of the water
heater•
2. Open
the cold water
supply
valve to the water
heater•
NOTE:
The cold
water
supply
valve
must
be left open
when
the water
heater
is in use.
3. To insure
complete
filling
of the tank,
allow
air to exit by
opening
the nearest
hot water
faucet•
Allow
water
to run
until a constant
flow
is obtained•
This will let air out of the
water
heater
and the piping•
4. Check
all new water
piping for leaks.
Repair
as needed.
Converting
the Lower Element
These
instructions
only cover the conversion
of the convertible
element,
read this entire
manual
before
attempting
to install
or
operate
the water
heater•
The water
heater
is factory
set to
operate
at 3800 watts.
The lower
element
can be converted
to
operate
at 5500
watts.
Refer
to "Facts
to Consider
About
the
Convertible
Lower
Element"
section.
The Upper
Element,
(if double
element
model)
is a conventional
3800 watt element
which
only operates
at its rated wattage
on
240 volts.
(See rating
plate on the water
heater•
The lower
Element
of the water
heater
can be converted
from
operation
at 3800
watts to 5500
watts
on a 240 volt system.
After reading
these
instructions
and this manual,
if you do not
understand
any portion
call Sears
Service
Center•
Fire Hazard / Electric
Shock
Hazard
®
®
Do not use this water heater with
any voltage other than shown on the
model rating plate.
Failure to use the correct voltage
shown on the model rating plate
could result in death, serious bodily
injury, or property damage.
Before
making
the conversion
to 5500 watts, check the (1) power
supply..,
must be 240 volts, (2) wiring...
10 gauge
AWG @
Type TW, 60°C or equivalent,
and (3) Circuit
breakers
or fusing
• . .capable
of 30 amp
loading.
Also,
the
installation
must
conform
with this manual,
local codes
and electric
utility rules•
Failure
to comply
can
result
in DEATH,
SERIOUS
BODILY
INJURY,
OR PROPERTY
DAMAGE.
NOTE:
Whether
or not the element
conversion
is made
the
model
rating plate
must be marked.
Using a hard point ink pen,
check the appropriate
block within
the model
rating
plate, which
is located
adjacent
to the lower access
panel.
ELECTRIC
O
LISTED
WATER HEATER
932N
CAPACITY
MODEL
NUMBER
U.S.
GAL.
SERIAL
NUMBER
FACTORY
EQUIPPED
WITH
MAXIMUM
UPPER
LOWER
CHECK
HERE
WORKING
ELEMENT
ELEMENT
MAXIMUM
VOLTS
IF]NSTALLEDAS
PRESSURE
WATTS
WATTS
WATTS
A.C. ONLY
FACTORY
EQUIPPED
P.S.I.
OPTIONAL
WATTAGE
UPPER
LOWER
ELEMENT
ELEMENT
MAXIMUM
CHECKHERE
WATTS
WATTS
WATTS
IF CONVERTED
WARNING
SEE CONVERSION
INSTRUCTION
FIGURE 11.
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power miser 6153.326162153.326163153.326264153.326265

Table of Contents