is made withanyliveelectrical part. T hedischarge opening
must not b eblocked orreduced insize under any circumstances.
Excessive length, over30feet(9.14 m),oruseofmore than
fourelbows c ancause restriction andreduce thedischarge
capacity ofthevalve.
Water Damage
Hazard
• Temperature-pressure
relief valve discharge
pipe must terminate
at adequate
drain.
No valve or other obstruction
is to be placed
between
the relief
valve and the tank.
Do not connect
tubing
directly
to discharge
drain
unless
a 6 inch air gap is provided.
To prevent
bodily
injury, hazard
to life, or property
damage,
the relief valve
must
be allowed
to discharge
water in quantities
should
circumstances
demand.
If the discharge
pipe is not connected
to a drain
or
other
suitable
means,
the water
flow
may
cause
property
damage.
The Discharge
Pipe:
Shall
not be smaller
in size than
the outlet
pipe size of the
valve,
or have any reducing
couplings
or other
restrictions.
Shall
not be plugged
or blocked.
Shall
be of material
listed
for hot water
distribution.
Shall
be installed
so as to allow complete
drainage
of both
the temperature-pressure
relief valve, and the discharge
pipe.
Shall
terminate
at an adequate
drain.
Shall
not have any valve between
the relief valve
and tank.
Water
temperature
over
125°F
(52°C) can cause severe
burns
instantly resulting in severe injury
or death.
Children,
the elderly,
and the
physically
or mentally
disabled
are at highest risk for scald injury.
Feel
water
before
bathing
or
showering.
Temperature
limiting valves are
available.
Read instruction
manual for safe
temperature
setting.
The
temperature-pressure
relief
valve
must
be manually
operated
at least once a year.
Caution
should
be taken to ensure
that
(1)
no one
is in front
of or around
the outlet
of the
temperature-pressure
relief
valve
discharge
line, and (2) the
water
manually
discharged
will not cause
any bodily
injury or
property
damage
because
the water
may be extremely
hot.
If after manually
operating
the valve,
it fails to completely
reset
and continues
to release
water, immediately
close the cold water
inlet to the water
heater,
follow
the draining
instructions,
and
replace
the temperature-pressure
relief valve
with a new one.
A_ERNATE
SHUT-OFF
VALVE
COLD
VALVE LOCATION
CONDUIT -I
TEMPERATURE-
/1
PRESSURE
RELIEF VALVE
DISCHARGE
PiPE
_(DO
NOT CAP
OR PLUG)
FLOOR DRAIN
FIGURE 10.
Temperatu
re=Pressu re Relief Valve -
Optional
Location
An
optional
temperature-pressure
relief
valve
location
is
provided
on the jacket
top.
If the top location
is preferred,
the temperature-pressure
relief
valve
in the side location
and the counter-sunk
plug in the top
location
can be interchanged.
Be sure
to use new pipe joint
compound
or put two to three
turns of teflon tape around the threaded
ends of the temperature-
pressure
relief
valve
and counter-sunk
plug
when
reinstalling
these
parts.
TEMPERATURE-
COLD
PRESSURE
HOT
SHUT-OFF
VALVE
BACKSIDE
OF HEATER
DISCHARGE
PiPE
-(DO
NOT CAP
OR PLUG)
11
FIGURE 10A.