Maytag MED9700S - Electric Dryer Use And Care Manual page 18

Use and care guide
Hide thumbs Also See for MED9700S - Electric Dryer:
Table of Contents

Advertisement

Available languages

Available languages

Alternate
installations
for
close clearances
Venting
systems come
ill many varieties.
Select the type best for your installation.
Two close-
clearance
installations
are shown.
Refer to the manufacturer's
instructions.
f
i
A
aL_[ =---_
_===_f../,
V,';'"
i,';"
X
I
A. Over-the-top installation (also available with one offset elbow)
B. P_riscope h_stallation
NOTE: The following
kits for close clearance
alternate
installations
are available
for purchase.
Please see the "Assistance
or Service"
section
to order.
Over-the-Top
Installation:
Part Number
4"_96028
Periscope
Installation
(For use with
dryer vent to wall vent mismatch/:
Part Number
4396037
- 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number
4396011
- 18" (45.72
cm) to 29" (73.66
cm) mismatch
Part Number
4396014
- 29" (73.66
cm) to 50" (127 cm) mismatch
Special
provisions for mobile home installations
The exhaust
vent must be securely
fastened
to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath the mobile
home.
lerminate
the exhaust
vent
outside.
Determine
vent path
Select the route that will provide
the straightest
and most direct
path outdoors.
Plan the installation
to use the fewest
number
of elbows
and turns.
When
using elbows
or making
turns,
allow as much
room as possible.
Bend vent gradually
to avoid kinking.
Use the fewest 90 ° turns possible.
Determine
vent length
and elbows
needed
for best drying
performance
Use the following
Vent system chart to determine
type of vent material
and hood
combinations
acceptable
to use.
NOTE:
Do not use vent runs longer than those specified
in the Vent system chart.
Exhaust
systems longer than those specified
will:
Shorten
the life of the dryer.
Reduce performance,
resulting
in longer drying
times and increased
energy
usage.
[he Vent system chart provides
venting
requirements
that will
help to achieve
the best drying
performance.
Vent
system
chart
NOTE: Side and bottom
exhaust
installations
have a 90 ° turn inside the dryer. Io determine
maximum
exhaust
length,
add one 90 ° turn to the chart.
Number
of 90 °
Type of vent
Box or Iouvered
Angled hoods
turns or elbows
hoods
0
Rigid metal
64 ft (20 rn)
58 ft (17.7 rn)
Flexible
metal
36 ft (11 m/
28 ft 18.5 m/
1
Rigid metal
54 ft (I 6.5 m)
48 ft (14.6 m)
Flexible metal
31 ft (9.4 m)
23 ft (7 m)
2
Rigid metal
44 ft (13.4 m)
38 ft (11.6 m)
Flexible metal
27 ft (8.2 m)
19 ft (5.8 m)
3
Rigid metal
35 ft (10.7 m)
29 ft (8.8 m)
Flexible metal
25 ft (7.6 m)
17 ft (5.2 m)
4
Rigid metal
27 ft (8.2 m)
21 ft (6.4 m)
Flexible metal
23 ft 17 m)
15 ft (4.6 m)
18