Read And Write Frame Error Counter Page Codes 34H, 35H - Sony AIT-SDX560 Product Specifications Manual

5.25" model
Table of Contents

Advertisement

LOG SENSE
Executing Mechanism Commands
Forward-ATF-On
Spool-Forward
Thread
Un-tension
Reverse
Spool-Reverse
Unthread
Stop
Eject
Still
Forward
Load
Re-tension
Re-start
Pinch-On
Pinch-Off
Diagnostics
7.6.9.

Read and Write Frame Error Counter Page Codes 34h, 35h

The Read Write Error Counter Page has the following format. All fields in these logs are initialized to ZERO in the
following circumstances:
At Power ON
After a cassette loading
After a user sends a request for initialization through Log Select
After a reset
Following configuration for error rate testing
Table 7-26: LOG PAGE Frame Error Counters (34h, 35h)
Bit
7
Byte
0
Reserved
1
2
(MSB)
3
4
(MSB)
5
6
0 (DU)
7
8
n
Frame Error Counter Page (Read 35h)
Frame Error Counter Page (Write 34h)
Parameter Code: This identifies which parameter of data is being transferred. The following codes are supported
for each Error Counter Page.
SONY AIT-2 Turbo drive SDX-560V series Ver.1.0
01h
07h
0Fh
10h
11h
17h
20h
21h
22h
23h
30h
31h
32h
33h
36h
37h
80h
6
5
4
Page Length (38h/48h)
Parameter Code
1 (DS)
0 (TSD)
0 (ETC)
Parameter Length (n-3)
Parameter Value
7. ATAPI Packet Command Specification
3
2
Page Code (34h or 35h)
Reserved
00 (TMC)
1
0
(LSB)
(LSB)
Reserved
0 (LP)
7-19

Advertisement