Installation; Installation Requirements - GE GEH6.0-3U-20 User Manual

Hybrid inverter
Table of Contents

Advertisement

User Manual V1.0-2023-10-30

5 Installation

5.1 Installation Requirements

Installation Environment Requirements
1. Do not install the equipment in a place near flammable, explosive, or corrosive materials.
2. Do not install the equipment in a place that is easy to touch, especially within children's reach. High
temperature exists when the equipment is working. Do not touch the surface to avoid burning.
3. Avoid the water pipes and cables buried in the wall when drilling holes.
4. Install the equipment in a sheltered place to avoid direct sunlight, rain, and snow. Build a sunshade
if it is needed.
5. The place to install the equipment shall be well-ventilated for heat dissipation and large enough for
operations.
6. The equipment with a high ingress protection rating can be installed indoors or outdoors. The
temperature and humidity at the installation site should be within the appropriate range.
7. Install the equipment at a height that is convenient for operation and maintenance, ensure that
the equipment's indicator lights, all labels are easy to view, and the wiring terminals are easy to
operate.
8. The altitude to install the inverter shall be lower than the maximum working altitude 4000m
9. Install the equipment away from electromagnetic interference. If there is any radio or wireless
communication equipment below 30MHz near the equipment, you have to:
Add a multi-turn winding ferrite core at the DC input line or AC output line of the inverter, or add
a low-pass EMI filter.
Install the inverter at least 30m far away from the wireless equipment.
10. The DC and communication cables between the battery and inverter should be less than 3 meters.
Please ensure that the installation distance between the inverter and the battery meets the cable
length requirements.
27
05
Installation