Install The Protectorsystem - Craftsman 139.53918D Owner's Manual

Hide thumbs Also See for 139.53918D:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
STEP
11
Install The ProtectorSystem ®
The safety reversingsensormust be connectedand aligned
correctlybefore the garage door opener will move in the down
direction.
IMPORTANTINFORMATIONABOUT
THE SAFETYREVERSING SENSOR
When properly connected and aligned, the sensor will detect an
obstacle in the path of its electronic beam. The sending eye (with
an amber indicator light) transmits an invisible light beam to the
receiving eye (with a green indicator light). If an obstruction
breaks the light beam while the door is closing, the door will stop
and reverse to full open position, and the opener lights will flash
10 times.
The units must be installed inside the garage so that the sending
and receiving eyes face each other across the door, no more than
6" (15 cm) above the floor. Either can be installed on the left or
right of the door as long as the sun never shines directly into the
receiving eye lens.
The mounting brackets are designed to clip onto the track of
sectional garage doors without additional hardware.
Be sure power is NOTconnected to the garage door opener
BEFORE installing the safety reversing sensor.
To prevent SERIOUSINJURY or DEATHfrom a closing garage
door:
• Correctly connect and align the safety reversing sensor. This
required safety device MUST NOT be disabled.
• Install the safety reversing sensor so beam is NO HIGHER
than 6" (15 cm) above garage floor.
If it is necessaryto mount the units on the wall, the brackets
must be securely fastened to a solid surface such as the wall
framing. Extension brackets (see accessories) are available if
needed. If installing in masonry construction, add a piece of wood
at each location to avoid drilling extra holes in masonry if
repositioning is necessary.
The invisible light beam path must be unobstructed. No part of
the garage door (or door tracks, springs, hinges, rollers or other
hardware) may interrupt the beam while the door is closing.
Reversing Sensor
Invisible Light B_,,,
_,_.._
Safety R, versing Sensor
6" (15 cm) max.
Protection Area
6" (15 cm) max.
above floor
above floor
Facing the doorfrom inside the garage
2O

Advertisement

Chapters

Table of Contents
loading

Table of Contents