Symptoms - Husqvarna AUTOMOWER 310E NERA Operator's Manual

Hide thumbs Also See for AUTOMOWER 310E NERA:
Table of Contents

Advertisement

7.3 Symptoms

If the product does not operate as usual, follow the symptoms table below. Speak to your Husqvarna customer
service if you cannot find the cause for the fault.
Symptoms
Edges of the lawn
are not satisfactorily
cut.
The product has diffi-
culty docking.
The product operates
at the incorrect time.
There is vibration in
the product.
The product oper-
ates, but the blade
disc does not rotate.
The product operates
for shorter periods
than usual between
charges.
Mowing and charg-
ing times are shorter
than usual.
38 - Troubleshooting
Cause
The blade disc guard for the EdgeCut blade
disc is clogged.
The edges of the lawn were not cut before
the installation of the product.
The grass is thick and grows quickly.
The guide wire is not put straight in a line
and correct distance from the charging sta-
tion.
The guide wire is not put in the slot in the
charging station plate.
The charging station is not on a level sur-
face.
The time or the date in the product is not
correct.
The start and stop times for operating are
incorrect.
The cutting system is not in balance because
of damaged blades.
The cutting system is not in balance because
of too many blades in the same position.
Different thickness of blades are installed on
the product.
The product searches for the charging sta-
tion, or is moving to the starting point.
Grass or other object causes a blockage to
the blade disc.
The battery is at the end of its life cycle.
Blunt blades. More energy is necessary
when cutting the grass.
The battery is at the end of its life cycle.
Action
Clean the blade disc guard for the EdgeCut
blade disc.
Use a grass trimmer to cut the edges of the
lawn.
Increase the scheduled cutting time for the
product.
Do a check of the installation of the charging
To install the charging sta-
station. Refer to
tion on page 16
Make sure that the guide wire is put straight
in a line and put in the slot in the charging
To install the guide
station plate. Refer to
wire on page 18 .
Put the charging station on a level surface.
To examine where to put the charg-
Refer to
ing station on page 12 .
Set the time or date. Refer to
page 23 .
Schedule settings. Refer to
Change the
Schedule on page 20 .
Examine the blades and screws and replace
them if necessary. Refer to
the blades on page 30 .
Do a check that only one blade is attached at
each screw.
Do a check if the blades are of different thick-
ness and replace if necessary.
Usual operation for the product. The blade
disc does not rotate when the product is
searching for the charging station.
Remove and clean the blade disc. Refer to
Clean the product on page 28 .
Replace the battery. Refer to
the blades on page 30 .
Replace the blades. Refer to
the blades on page 30 .
Replace the battery. Refer to
page 29 .
2369 - 001 - 05.02.2024
Time & date on
Replacement of
Replacement of
Replacement of
Battery on

Advertisement