Alarm
Description
EF5
Unbalanced load
EF6
Reset
Power supply frequency of
EH1
appliance outside the limits
EH2
Supply voltage too high
EH3
Supply voltage too low
EH4
0Watt relay malfunction
Inconsistency between FCV relay (in
EHE
the main board) and safety
"sensing" circuit
Safety sensing circuit faulty (wrong
EHF
input voltage to microprocessor)
2010 dmm
Possible fault
Final spin phases skipped.
If it continues, replace the main board.
Problem with the power supply network (incorrect/disturbed); Main
PCB faulty.
Problem with the power supply network (incorrect/disturbed); Main
PCB faulty.
Problem with the power supply network (incorrect/disturbed); Main
PCB faulty.
Main circuit board faulty.
Faulty cabling; Main circuit board faulty
Main circuit board faulty
70/96
Machine status/action
----------------
START/RESET
No action to be taken
Wait for nominal
frequency conditions
Wait for nominal
voltage conditions.
Wait for nominal
voltage conditions.
----------------
Safety drain cycle
Cycle stops with door open
Safety drain cycle
Cycle stops with door open
Reset
----------------
ON/OFF
ON/OFF
ON/OFF
ON/OFF
RESET
RESET
RESET