  • Page 1 Cisco Firepower 1010 Series Hardware Installation Guide First Published: 2019-07-24 Last Modified: 2023-06-22 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: https://www.cisco.com/c/en/us/about/legal/trademarks.html.
  • Page 3 Maintain Safety with Electricity Prevent ESD Damage Site Environment Site Considerations Power Supply Considerations Rack Configuration Considerations C H A P T E R 3 Mount the Chassis Unpack and Inspect the Chassis Desktop-Mount the Chassis Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 4 Connect to the Console Port with Mac OS X Connect to the Console Port with Linux C H A P T E R 5 Installation, Maintenance, and Upgrade Install the FIPS Opacity Shield Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 5: Table Of Contents

    Power Cord Specifications, on page 16 Features The Cisco Firepower 1010 and 1010E are a series of compact network security appliances in the Cisco Firepower family. The Firepower 1010 is first supported in Firepower Threat Defense (FTD) Version 6.4 and ASA Version 9.12.
  • Page 6 Use to access management through an external system USB Mini B port One USB Mini B Use to access management through an external system USB port One USB 3.0 Type A Use to attach an external device such as storage Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 7 System power is controlled by the power cord; there is no power button. To shut down the Firepower 1010 or 1010E, remove the AC power supply. Power cord socket The chassis is powered on when you plug in the AC power supply. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 8 Storage One 200-GB M.2 SATA SSD drive The drive is used by the software; there is no user access to the drive. The drive is not field-replaceable; you must return the chassis to Cisco for drive replacement. Rubber feet Four rubber feet on the bottom of the chassis The rubber feet are needed for proper cooling.
  • Page 9 Overview Features Feature 1010 1010E — Security standards certifications Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 10 Processing Standards (FIPS) 140-2 on FTD 6.4.x and FX-OS 2.6.x • Department of Defense Information Network Approved Product List (DoDIN APL) • US Government Compliance for IPv6 (USGv6) on FTD 7.0.x— Certification Approval Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 11 • RJ-45 (8P8C) port—Supports RS-232 signaling to an internal UART controller. The RJ-45 console port does not support a remote dial-in modem. You can use a standard management cable (Cisco part number 72-3383-01) to convert the RJ45-to-DB9 connection if necessary.
  • Page 12: Package Contents

    Firepower 1010 to a network so that the IT department can onboard the device to CDO and configure it remotely. CDO supports Firepower Threat Defense (FTD) version 6.7 and later. The following figure shows the QR code sticker. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 13: Serial Number And Digital Documentation Portal Qr Code

    Digital Documentation Portal QR code that points to the getting started guide, the regulatory and compliance guide, the easy deployment guide, and the hardware installation guide. The following figure shows an example compliance label found on the bottom of the chassis. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 14: Front Panel

    Figure 6: Firepower 1010 and 1010E Front Panel Rear Panel The following figure shows the rear panel of the Firepower 1010 and 1010E. See Status LEDs, on page 11 for a description of the LEDs. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 15: Status Leds

    The network port LEDs are at the top sides of each network port. The following figure shows the status LEDs on the rear panel and on the cover of the chassis. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 16 Power, Status, and Active LEDs on top of chassis The following figure shows all of the LEDs on the rear panel of the Firepower 1010 and 1010E and describes their states. Figure 9: Rear Panel LEDs Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 17 The LED is green always unless the chassis • Green—Link established. in a high availability pair. • Green, flashing—Link activity. • Amber—When the chassis is in a high availability pair, the LED is amber for the standby unit. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 18: Hardware Specifications

    Note Use the power supply (part number 341-100765-01) that shipped with the chassis. It supports PoE+. PoE+ is first Note supported in FTD Version 6.5 and ASA Version 9.13. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 19: Product Id Numbers

    Cisco Firepower 1010E ASA desktop appliance FPR1010-NGFW-K9 Cisco Firepower 1010 NGFW desktop appliance FPR1010E-NGFW-K9 Cisco Firepower 1010E NGFW desktop appliance FPR1K-DT-ACY-KIT Cisco Firepower 1010 and 1010E accessory kit FPR1K-DT-PWR-AC Cisco Firepower 1010 and 1010E 150-W power supply Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 20: Power Cord Specifications

    Only the approved power cords or jumper power cords provided with the chassis are supported. The following power cords are supported. Figure 10: Argentina (CAB-AC-C5-ARG) Plug: IRAM 2073 Cord set rating: 2.5 A, 250 V Connector: IEC 60320/C5 — Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 21 Figure 12: Brazil (CAB-AC-C5-BRA) Plug: NBR 14136 Cord set rating: 2.5 A, 250 V Connector: IEC 60320/C5 — Figure 13: Canada (CAB-AC-C5) Plug: NEMA 5-15P Cord set rating: 2.5 A, 125 V Connector: IEC 60320/C5 — Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 22 Plug: CEE 7 VII Cord set rating: 2.5 A, 250 V Connector: IEC 60320/C5 — Figure 16: India (CAB-AC-C5-IND) Plug: IS 1293 Cord set rating: 2.5 A, 250 V Connector: IEC 60320/C5 — Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 23 Figure 18: Japan (CAB-AC-C5-JAP) Plug: JIS C8303 Cord set rating: 3 A, 125 V Connector: IEC 60320/C5 — Figure 19: Korea (CAB-AC-C5-KOR) Plug: KSC 83205 Cord set rating: 3.0 A, 250 V Connector: IEC 60320/C5 — Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 24 Figure 21: Switzerland (CAB-AC-C5-SWI) Plug: SEV 1011 Cord set rating: 2.5 A, 250 V Connector: IEC 60320/C5 — Figure 22: Taiwan (CAB-AC-C5-TWN) Plug: CNS 10917-2 Cord set rating: 2.5 A, 125 V Connector: IEC 60320/C5 Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 25 Overview Power Cord Specifications Figure 23: United Kingdom (CAB-AC-C5-UK) Plug: BS1363A/SS145 Cord set rating: 2.5 A, 250 V Connector: IEC 60320/C5 — Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 26 Overview Power Cord Specifications Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 27 SAVE THESE INSTRUCTIONS Warning Statement 1004 Installation Instructions Read the installation instructions before using, installing, or connecting the system to the power source. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 28 This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 29 Statement 9001 Product Disposal Ultimate disposal of this product should be handled according to all national laws and regulations. Position the Chassis Desktop-Mount the Chassis, on page 32 for information on desktop-mounting the chassis. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 30 • Wear safety glasses if you are working under any conditions that might be hazardous to your eyes. • Do not perform any action that creates a potential hazard to people or makes the equipment unsafe. • Never attempt to lift an object that is too heavy for one person. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 31 Placing equipment too close together with inadequate ventilation and inaccessible panels can cause system malfunctions and shutdowns. Improper placement can also make it difficult for you to access the chassis for maintenance. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 32 • Several styles of AC-input power supply cords are available for the chassis; make sure that you have the correct style for your site. • Install an uninterruptible power source for your site, if possible. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 33 • Baffles can help to isolate exhaust air from intake air, which also helps to draw cooling air through the chassis. The best placement of the baffles depends on the airflow patterns in the rack. Experiment with different arrangements to position the baffles effectively. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 34 Installation Preparation Rack Configuration Considerations Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 35 Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready: • Invoice number of shipper (see the packing slip) • Model and serial number of the damaged unit • Description of damage • Effect of damage on the installation Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 36 (rear panel up), the holes should be 6.826 inches apart. For side to side orientation, the holes should be 5.154 inches apart. The wall-mount kit (part number 69-100647-01) contains the following items: • Wall-mount bracket (part number 700-118506-01) Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 37 Figure 26: Wall-Mount Bracket Horizontal mounting Vertical mounting Step 3 Attach the wall-mount bracket to the chassis using the three Phillips M3 x 6-mm screws. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 38 Pick up the chassis, align the screws in the anchors with the holes in the bottom of the wall-mount bracket, move the chassis toward the wall until the screw heads are in the wall-mount bracket, and then slide it down until it rests on the screws. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 39 • Four Phillips 10-32 x 0.75-inch screws (part number 48-0441-01); depending on your rack type, use these screws to secure the sliding-rack tray to your rack. Step 1 Install the cable guides on the rack shelf: Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 40 Place the chassis with the top facing down on a large, stable work area. Step 3 Invert the sliding rack tray and position it on the chassis. You can mount the chassis with the front or rear panel facing front. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 41 Tighten the three M3 x 7-mm screws to lock the chassis into place on the sliding rack tray (see the figure above). Step 6 Carefully turn the sliding rack tray right-side up. Step 7 Install the power supply in the sliding rack tray behind the chassis. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 42 If the rear sliding stop is not touching the power supply, loosen the two screws, slide the stop up to touch the power supply, and then retighten screws. c) Re-engage the Velcro straps and tighten them to secure the power supply. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 43 Use the second sliding rack tray and remaining three M3 x 7-mm screws to install a second chassis to the sliding rack tray and then onto the rack shelf (see Step 3). Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 44 You can now attach your power supply cord and run it through the cable guides. What to do next Install the cables according to your default software configuration as described in the Cisco Firepower 1010 Getting Started Guide. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 45 The drivers are OS-specific and not tied to the vendor of the console cable manufacturer. Step 2 Install the driver. Step 3 Connect a 5-pin USB Mini B to the console port as shown in the following figure. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 46 Follow the instructions to complete the driver installation. Step 6 To communicate with the chassis, start a terminal emulator application. This software should be configured with the following parameters: • 9600 baud • 8 data bits Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 47 /dev# ls -ltr *ACM* crw-r--r-- 1 root root 188, 0 Jan 14 18:02 ttyACM0 root@usb-suse /dev# Step 4 Connect to the USB port with the following command followed by the chassis USB port speed Example: Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 48 Connect to the Console Port Connect to the Console Port with Linux root@usb-suse /dev# screen /dev/ttyACM0 9600 Step 5 To disconnect the Linux USB console from the Terminal window, enter Ctrl-a followed by : then quit. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 49 Because the FIPS opacity shield covers the serial number on the chassis, the CO should copy the serial number and store it in a secure place. The serial number is needed when you call Cisco TAC. See Serial Number and Digital Documentation Portal QR Code, on page 9 for the location of the serial number.
  • Page 50 Install the FIPS cover by holding the chassis right-side up and sliding the chassis into the FIPS cover front panel first. Figure 35: Install Chassis into FIPS Cover Step 4 Turn the chassis with the FIPS cover installed over and install the three screws. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 51 The figure shows the bottom of the chassis where you place three of the TELs. Allow the TELs to cure for a minimum of 12 hours. Any deviation in the placement of the TELs means the chassis is not in FIPS mode. Caution Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 52 See the following procedures for how to place the chassis in FIPS mode: • See the "Security Certifications Compliance" chapter in the your software version configuration guide for the procedure to enable FIPS mode. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 53 • See the fips enable command in the Cisco ASA Series Command Reference, A-H Commands for the ASA procedure to enable FIPS mode. What to do next See the Cisco Firepower 1010 Getting Started Guide for further configuration information. Cisco Firepower 1010 Series Hardware Installation Guide...
  • Page 54 Installation, Maintenance, and Upgrade Install the FIPS Opacity Shield Cisco Firepower 1010 Series Hardware Installation Guide...