Switching Off The Beep; Technical Specifications - Makita LD060P Instruction Manual

Laser distance measure
Hide thumbs Also See for LD060P:
Table of Contents

Advertisement

Available languages

Available languages

Switching off the beep
Press and hold simultaneously for 5
seconds:
The beep is switched off.
To reactivate it, press and hold for 5 seconds.
Appendix
Display Notices
All display notices are either displayed with (i) or
"Error". The following errors can be corrected.
(D
Cause
Correction
204
Calculation error
Repeat procedure
252
Temperature too
high
Let device cool down.
253
Temperature too
low
Warm device up
255
Received signal too
weak, time for a
measurement too
long.
Use a target plate
256
Received signal too
strong
Use target plate (gray
side)
257
Faulty measure¬
ment, too much
background light
Use target plate (brown
side)
Makita LD060P
CD
Cause
Correction
258
Outside of the range
of measurement
Select measurement
distance within the
range of measurement
Error
Cause
Correction
Error
Hardware error
Should this message
remain active after
switching the instru¬
ment off and on several
times, please contact
the dealerhip.
Technical Specifications
Range
0.05 m to 60 m*
Measuring accuracy (2 a)
typically ± 1.5 mm**
Smallest unit displayed
1 mm
Laser class
2
Laser type
635 nm, < 1 mW
Protection against
IP 54, dust-proof,
splashes and dust
splash-proof
Autom. power off:
Laser
after 60 s
Instrument
after 180 s
Illumination
/
Folding out endpiece
V
Battery life,
up to
Type 2 x AAA
5 000 measurements
Dimension
112 x 43 x 25 mm
Weight
100 g