Download Print this page

Lenovo ThinkStation P5 Manual page 29

Storage configurator
Hide thumbs Also See for ThinkStation P5:

Advertisement

6. If there is a 2
nd
SATA drive to be installed, repeat the steps above for the
2nd drive to be installed in the internal bay. An additional SATA signal
cable will need to be obtained and plugged into the open SATA2 port on
the motherboard. The SATA 1 port is always populated, even if there was
no drive in the system. See the
7. Plug in the SATA power and signal cables into both drives.
8. If the fan and fan holder did not come together as a set it will be necessary
to insert the fan into the fan holder. Standard installation will be with the
label on the fan to the inside of the holder. When installed properly the
center of the fan should have no label visible (1). Rotate the fan in the
holder, as needed, so that the power cable can easily be inserted into the
power cable slot on the fan holder (2).
Appendix
for additional parts information.
29