Chapter 6 Maintenance — Light source/temperature/filter indicators
Light source/temperature/filter indicators

When an indicator lights up

If a problem occurs inside the projector, the slight source indicator <光源>/temperature indicator <温度>/filter
indicator <过滤网> will inform you by lighting or blinking. Check the status of the indicators and take following
measures.
Attention
f When switching off the projector to deal with problems, make sure to follow the procedure in "Switching off the projector" (x page 61).
Light source indicator <光源>
Indicator status
Some of the elements of the light
Lighting in red
source are defective and the light
output has decreased.
Blinking in red
The light source is turned off since the
(1 time)
projection lens cannot be detected.
Blinking in red
The light source does not light up,
(2 times)
or the light source turns off while the
Blinking in red
projector is in use.
(3 times)
Note
f If the light source indicator <光源> is still lit or blinking after taking the measures, set the <主电源> switch to <关>, and ask your dealer for
repairs.
Status
f Turn the <主电源> switch to <关> (x page 61), and turn on the power
again.
f Turn off the power and mount the projection lens again. (x page 39)
f Turn the <主电源> switch to <关> (x page 61), and turn on the power
again.
f Turn the <主电源> switch to <关> (x page 61), and turn on the power
again.
Light source indicator < 光源 >
Temperature indicator < 温度 >
Filter indicator < 过滤网 >
Solution
ENGLISH - 197