OPERATION
6

6.4.3 Diagnosis messages

These settings make it possible to change the status signal of the respective diagnosis message
(status group).

6.4.4 Optical keys

This function can deactivate the optical keys. In the display, the switched off state of the optical
keys is represented by a lock 1.
Figure 6-7: Indicator for optical keys in the display
1 "Lock" indicate that optical keys are switched off
.

6.4.5 Graphic page

With this converter, the trend of the main measurement can be graphically displayed. The first
measurement on display page 1 is always defined as the main measurement.
• Menu C7.5.1 defines the range for the trend indicator (manual or automatic).
• Menu C7.5.2 defines the range for manual setting.
• Menu C7.5.3 defines the time span for the trend indicator.

6.4.6 Save settings

This function allows all settings to be stored in a memory.
• Backup 1: Saves settings in backup memory area 1
• Backup 2: Saves settings in backup memory area 2

6.4.7 Load settings

This function allows the complete stored settings to be loaded again.
• Backup 1: Loading from backup - memory 1
• Backup 2: Loading from backup - memory 2
• Factory: Uploading the original factory settings