HTC T6/RT6/X6/RX6
Symbol
OVERVOLTAGE
PHASE LOSS
RADIO VOLTAGE LOW
UNDERVOLTAGE
62
Error Message
Fault description
Input voltage too high.
Phase error incoming
supply.
Low voltage radio
receiver.
Low voltage.
Troubleshooting
Action
Error on incoming
supply.
Incoming supply has
lost one or more
phases. Check
incoming supply.
Check control voltage.
Check battery voltage.
Check cabling to radio
receiver.
Check cable area and
cable length. Error on
incoming supply.
Emergency stop
activated.
D002998, 02.00