Installation Manual
AIR-TO-WATER HYDROMODULE + TANK
WH-ADC0509L3E5, WH-ADC0509L3E5AN, WH-ADC0509L6E5, WH-ADC0509L6E5AN
CAUTION
R290
REFRIGERANT
This AIR-TO-WATER HYDROMODULE + TANK operates in
combination with an outdoor unit containing refrigerant R290.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to National, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance and/or service of this product.
SAFETY PRECAUTIONS
Read the following "SAFETY PRECAUTIONS" carefully before installation of Air-To-Water Hydromodule + Tank (here after referred to as "Tank Unit").
Electrical works and water installation works must be done by licensed electrician and licensed water system installer respectively. Be sure to use the correct
rating and main circuit for the model to be installed.
The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below.
Incorrect installation due to ignorance or negligence of the instructions will cause harm or damage, and the seriousness is classifi ed by the following indications.
Please leave this installation manual with the unit after installation.
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classifi ed by the symbols:
Symbol with white background denotes item that is PROHIBITED.
Symbol with dark background denotes item that must be carried out.
Carry out test run to confi rm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in instructions.
Please remind the customer to keep the operating instructions for future reference.
If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. Any unfi t method or
using incompatible material may cause product damage, burst and serious injury.
Do not use unspecifi ed cord, modifi ed cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical
appliances. Poor contact, poor insulation or over current will cause electrical shock or fi re.
Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.
Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing.
Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fi re.
Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, fl ame, sparks, or other sources of ignition.
Else, it may explode and cause injury or death.
WEB-ACXF60-51550-EN
Required tools for Installation Works
1 Philips screw driver
2 Level gauge
3 Electric drill, hole core drill
4 Hexagonal wrench (4 mm)
5 Spanner
6 Pipe cutter
7 Reamer
8 Knife
9 Gas leak detector
10 Measuring tape
11 Thermometer
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
CAUTION
CAUTION
CAUTION
WARNING
ENGLISH
12 Megameter
13 Multimeter
14 Torque wrench
18 N•m (1.8 kgf•m)
55 N•m (5.5 kgf•m)
58.8 N•m (5.8 kgf•m)
65 N•m (6.5 kgf•m)
117.6 N•m (12.0 kgf•m)
15 Hand gloves
This symbol shows that this equipment uses
a fl ammable refrigerant with safety A3 group
per ISO 817. If the refrigerant is leaked,
together with an external ignition source,
there is a possibility of fi re / explosion.
This symbol shows that the Installation
Manual should be read carefully.
This symbol shows that a service personnel
should be handling this equipment with
reference to the Installation Manual.
This symbol shows that there is information
included in the Operation Manual and/or
Installation Manual.
1

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic WH-ADC0509L3E5

  • Page 1 ENGLISH Installation Manual AIR-TO-WATER HYDROMODULE + TANK WH-ADC0509L3E5, WH-ADC0509L3E5AN, WH-ADC0509L6E5, WH-ADC0509L6E5AN Required tools for Installation Works CAUTION 1 Philips screw driver 12 Megameter 2 Level gauge 13 Multimeter R290 3 Electric drill, hole core drill 14 Torque wrench 18 N•m (1.8 kgf•m) 4 Hexagonal wrench (4 mm) 55 N•m (5.5 kgf•m)
  • Page 2 • Strongly recommended to make permanent connection to a circuit breaker. 8 For Tank Unit WH-ADC0509L3E5 and WH-ADC0509L3E5AN: - Power Supply 1: Use approved 25A 2-poles circuit breaker with a minimum contact gap of 3.0mm. - Power Supply 2: Use approved 15/16A 2-poles circuit breaker with a minimum contact gap of 3.0mm.
  • Page 3 Attached accessories Field Supply Accessories (Optional) Part Model Specifi cations Maker Accessory part Qty. No. Accessory part Qty. 2-way valve kit Electromotoric Actuator SFA21/18 AC230V, 12 VA Siemens Adjustable Feet Packing for drain *Cooling model 2-port Valve VXI46/25 Siemens Wired PAW-A2W-RTWIRED Room thermostat AC230V...
  • Page 4: Select The Best Location

    TO DRILL A HOLE IN THE SELECT THE BEST LOCATION WALL AND INSTALL A Before choosing the installation site, obtain user approval. SLEEVE OF PIPING Install the Tank Unit in indoors with frost free weather proof location only. 1. Make a through hole. (Check pipe diameter and insulation thickness) 2.
  • Page 5 • Do not apply excessive force to pipes that may damage the pipes. Model Cool Heat • Choose proper sealer which can withstand the pressures and WH-ADC0509L3E5, WH-WDG05LE5* 14.3 14.3 temperatures of the system. WH-ADC0509L3E5AN, • Make sure to use two spanners to tighten the connection. Further WH-WDG07LE5* 20.1...
  • Page 6 Failure to connect the tube appropriately might causing the Tank Unit malfunction. Tank Unit Outdoor Unit Size (D) Drain Elbow and Hose Installation WH-ADC0509L3E5, • Fix the Drain Elbow 2 and Packing 3 to the bottom of Drain Water Hole WH-WDG05LE5* WH-ADC0509L3E5AN, WH-WDG07LE5* 4 x min 2.5 mm...
  • Page 7 ACCEPT PROHIBITED PROHIBITED CONNECTING REQUIREMENT For Tank Unit WH-ADC0509L3E5, WH-ADC0509L3E5AN with WH-WDG05LE5*, WH-WDG07LE5*, WH-WDG09LE5* • The equipment’s Power Supply 1 complies with IEC/EN 61000-3-2. • The equipment’s Power Supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply network.
  • Page 8 INSTALLATION OF REMOTE RECONFIRMATION CONTROLLER AS ROOM THERMOSTAT WARNING Be sure to switch off all power supply before performing each of • Remote Controller 1 mounted to the Tank Unit can be moved to the below checkings. the room and serve as Room Thermostat. CHECK WATER PRESSURE *(1 bar = 0.1MPa) Installation Location...
  • Page 9 3. Remove the top case from the bottom case. 5. For embedded type Preparation: Make 2 holes for screws using a driver. Mount the bottom case to the wall. Mount the top case. • Pass the wire through the hole •...
  • Page 10: Maintenance

    6. Reinstall the Cap of Discharge Port and Magnet Bar. TEST RUN 7. Re-charging the water to Space Heating / Cooling circuit if necessary (refer Section 5 for details.) 1. Before test run, make sure below items have been checked:- 8.
  • Page 11 APPENDIX 1 Variation of system This section introduces variation of various systems using Air-To-Water Heatpump and actual setting method. (NOTE) : For this model, both external room thermistor of Zone 1 and external room thermostat of Zone 1 must always be connected to main indoor PCB only regardless of Optional PCB (CZ-NS5P) connection.
  • Page 12 Connect fl oor heating or radiator directly to Tank Unit. Remote controller is installed on Tank Unit. Install separate external room thermistor (specifi ed by Panasonic) in the room where fl oor heating is installed. This is an application that uses external room thermistor.
  • Page 13 Connects pool heat exchanger directly to Tank Unit without using buffer tank. Install pool pump and pool sensor (specifi ed by Panasonic) at secondary side of the pool heat exchanger. Remove remote controller from Tank Unit and install in room where fl oor heating is installed.
  • Page 14 This is an application that connects the buffer tank to the Tank Unit. Buffer tank’s temperature is detected by buffer tank thermistor (specifi ed by Panasonic). Without connection of Optional PCB, external pump can be used for circulation in the fl oor heating circuit.
  • Page 15 2 How to fi x cable • For connection to Optional PCB 7 1. By connecting Optional PCB, 2 Zone temperature control can be achieved. Please connect mixing valves, water pumps and Connecting with external device (optional) thermistors in zone 1 and zone 2 to each terminals in Optional PCB. •...
  • Page 16: External Device

    Optional cables (from Optional PCB):   D-1 and D-2 Bushings are for: • External control cable • • External control cable Water sensor zone 1 cable • Outdoor air sensor cable • • Outdoor air sensor cable Water sensor zone 2 cable •...
  • Page 17 Solar sensor PAW-A2W-TSSO 70.53 2.106 93.05 2.508 Recommended External Device Specifi cation 124.24 3.003 • This section explains about the external devices (optional) 167.82 3.615 recommended by Panasonic. Please always ensure to use the 4.375 correct external device during system installation.
  • Page 18 3. Pull the CN-CNT cable through the hole in the bottom of the For optional pump. adaptor and re-attach the front cover to the back cover. Power supply: AC230V/50Hz, <500W Recommended part: Yonos 25/6: made by Wilo CN-CNT cable (Take care not to pinch the cable) •...
  • Page 19: System Installation

    3 System installation 3-1. Remote Controller Outline The LCD display as shown in this manual are for instructional purpose only, and may differ from the actual unit. Name Function A: Main screen Display information B: Menu Open/Close main menu C: Triangle (Move) Select or change item D: Operate Start/Stop operation...
  • Page 20 First time of power ON (Start of installation) 12:00am,Mon Initialization When power is ON, fi rstly initialization screen appears (10 sec) Initializing. « 12:00am,Mon When initialization screen ends, it turns to normal screen. Start « When any button is pressed, language Language 12:00am,Mon setting screen appears.
  • Page 21: Installer Setup

    Main Menu 12:00am,Mon System check Personal setup Service contact Installer setup Select Confi rm Confi rm to go into Installer setup « 3-2. Installer Setup System setup Optional PCB connectivity Yes/No  Only when the selection for Optional PCB is Yes Zone &...
  • Page 22 DHW defrost Yes/No Heating control Comfort/Effi ciency Heat-cool meter / *Tank meter / Elec. meter HP / Elec. meter 1 (PV meter) / External meter Elec. meter 2 (Total building) / Elec. meter 3 (Reserve) *Only available when Heat-cool meter select Yes Electrical anode Yes/No Compensation...
  • Page 23: System Setup

    3-3. System Setup 1. Optional PCB connectivity 12:00am,Mon System setup Initial setting: No Optional PCB connectivity If function below is necessary, please purchase and install Optional PCB. Zone & Sensor Please select Yes after installing Optional PCB. Heater capacity • 2-zone control •...
  • Page 24 6. Buffer Tank connection 12:00am,Mon System setup Initial setting: No Heater capacity Select whether it is connected to buffer tank for heating or not. Anti freezing If buffer tank is used, please set Yes. Connect buffer tank thermistor and set, T (T use to increase primary side temp Tank connection against secondary side target temp).
  • Page 25 Alternative mode Parallel mode operate boiler only operate heat pump only operate boiler and heat operate heat pump only pump simultaneously Outdoor temp. Outdoor temp. -10°C (setting from remote controller) -10°C (setting from remote controller) Advanced Parallel mode For heating For DHW tank operate boiler and heat operate heat pump only...
  • Page 26 12. External Error Signal System setup 12:00am,Mon Initial setting: No Bivalent connection Set when external error display unit is installed. External SW Turn on Dry Contact SW when error happened. Solar connection (NOTE) Does not display when there is no Optional PCB. External error signal When error occurs, error signal will be ON.
  • Page 27 15. External Compressor SW System setup 12:00am,Mon Initial setting: No External error signal Set when external compressor SW is connected. Demand control SW is connected to external devices to control power consumption, Open Signal will stop compressor’s operation. (Heating operation etc. are not cancelled). SG ready External compressor SW (NOTE) Does not display if there is no Optional PCB.
  • Page 28: Heating Control

    21. Pump fl owrate Initial setting: T System setup 12:00am,Mon Force heater If pump fl owrate setting is T, unit adjust pump duty to get different of water inlet Force defrost and outlet base on setting on * T for heating ON and * T for cooling ON in Defrost signal operation setup menu during room side operation.
  • Page 29: Operation Setup

    3-4. Operation Setup Heat 55°C 26. Water temp. for heating ON Initial setting: compensation curve Decide temperature of 4 points as shown Hot water in diagram temperature Set target water temperature to operate heating operation. Compensation curve: Target water temperature change in conjunction with 35°C outdoor ambient temperature change.
  • Page 30 31. ∆T for cooling ON Initial setting: 5°C Set temp difference between out temp & return temp of circulating water of Cooling operation. Return When temp gap is enlarged, it is energy saving but less comfort. When the gap gets smaller, energy saving effect gets worse but it is more comfortable. Return —...
  • Page 31: Service Setup

    37. Sterilization Initial setting: 65°C 10min ② Set timer to perform sterilization. 1 Set operating day & time. (Weekly timer format) 2 Sterilization temp (55~65°C) 3 Operation time (Time to run sterilization when it reached setting temp ①  ③ 5min ~ 60min) User shall set whether to use or not to use sterilization mode.
  • Page 32: Service And Maintenance

    4 Service and maintenance Check Water Pressure from Remote Controller If forget Password and cannot operate remote controller 1. Press SW and scroll to "System check". Press for 5 sec. 2. Press and scroll to "System information". Password unlock screen appears, press Confi rm and it shall reset. Password will become 0000.

This manual is also suitable for:

Wh-adc0509l3e5anWh-adc0509l6e5Wh-adc0509l6e5an

Table of Contents