System Maintenance
Upgrades
Note: Periodically repeat retrieving alarms to check alarm status until the softwareStageInProgress alarm is
cleared.
Step 4
Activate the new software load.
Command:
> request sw-activate gissue 19.1.1 validationTimer 01-30-00
Step 5
After the blade reboots, cancel the validation timer to accept the new load.
Command:
> request cancel-validation-timer accept true
Step 6
Verify that the new software load is accepted for the active and backup banks.
Command:
> show sw-version
Step 7
Retrieve alarms to verify if firmwareBackwardCompatibleAll alarm is raised.
Command:
> show alarms alarm-list
Step 8
Execute FW update on each blade if a firmwareBackwardCompatibleAll alarm is raised.
Command:
> request fw-update shelf-id x force true overwrite false
Note: x represents the shelf-id of each individual blade.
Step Result:
A firmwareInitInProgress is reported on the target blade.
Step 9
Retrieve alarms to verify firmwareInitInProgress alarm is cleared.
Command:
> show alarms alarm-list
Note: Periodically repeat retrieving alarms to check alarm status until the firmwareInitInProgress alarm is
cleared. The firmwareBackwardCompatibleAll alarm clears as well.
Caution: Waiting for firmwareInitInProgress alarm to clear may take 20...30 minutes depending on release
upgrade path. Wait until alarm clears before proceeding with operations on system.
·
Release 19.1.1
Issue 1.1, May 2021
413