Trouble Clearing

softwareReset

Entity Type
BDL1-3B11, BDL1-3R11

softwareStageInProgress

Entity Type
BDL1-3B11, BDL1-3R11

softwareVersionMismatch

Entity Type
COM
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
minor
non–service-
n/a
affecting
Probable Cause
A system software reset is in progress.
Service
Severity
Direction
Affected
major, non-
non–service-
n/a
alarmed
affecting
Probable Cause
Software staging is in progress.
Service
Severity
Direction
Affected
major
non–service-
n/a
affecting
Probable Cause
A mismatch failure of the file configuration
among the active banks has occurred.
Location
Description
NEND
Software Reset: TYPE=<unit type>
Suggested Corrective Action
No action is required. This alarm clears when the system
software reset completes.
Location
Description
NEND
Software Stage In Progress
Suggested Corrective Action
No action is required. The alarm automatically clears when
software staging completes.
Location
Description
NEND
Software Version Mismatch
Suggested Corrective Action
1. In a new turn-up, perform a WARM reset.
2. If the installed blade contains the desired software and
database, call Fujitsu for technical assistance at 1-800-
USE-FTAC (1-800-873-3822).
3. Download the latest release of software to all blades,
and switch to the new load. If any problems exist, call
Fujitsu for technical assistance at 1-800-USE-FTAC
(1-800-873-3822).
Fujitsu and Fujitsu Customer Use Only
333