Fujitsu 1FINITY L100 User Manual page 327

Table of Contents

Advertisement

System Maintenance
Trouble Clearing
Entity Type
1GEX
1GEX
1GEBT
1GEBT
1GEBT
1GEBT
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
critical
non–service-
transmit
affecting
Probable Cause
The optical power on the indicated transmit
1GEX interface is too high.
critical
non–service-
receive
affecting
Probable Cause
The optical power on the indicated receive
1GEX interface is too high.
minor
non–service-
transmit
affecting
Probable Cause
The optical power on the indicated transmit
1GEBT interface is too high.
minor
non–service-
receive
affecting
Probable Cause
The optical power on the indicated receive
1GEBT interface is too high.
critical
non–service-
transmit
affecting
Probable Cause
The optical power on the indicated transmit
1GEBT interface is too high.
critical
non–service-
receive
affecting
Probable Cause
The optical power on the indicated receive
1GEBT interface is too high.
Location
Description
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
None
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical receive power at the indicated port.
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical transmit power at the indicated port.
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical receive power at the indicated port.
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical transmit power at the indicated port.
NEND
Power Out of Specification–High: TYPE =
<unit type>
Suggested Corrective Action
Check the optical receive power at the indicated port.
Fujitsu and Fujitsu Customer Use Only