Init; Error Messages - AEG ACM 9 Manual

Table of Contents

Advertisement

Manual ACM 9 - ARE i9 release

3.5.11 INIT

INIT – Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the
parameters.
Input format: INIT<CR>
Hex:
49
ASCII:
'I'
Output (example): OK<CR>
Hex:
4F
ASCII:
'O'
The following parameters are set:
TOR 50
MD 2
CID 0
CN 0
LSTB 01101
LGT 01111

3.5.12 Error messages

Error messages and protocol errors are acknowledged by ARE i9 using an error code. The format is described below:
<NAK> '#' <error code> <CR>
Example error #02 (wrong parameter)
Hex:
15
ASCII:
<NAK>
The error code is comprised of a two digit ASCII coded number. Please note that for communication through ACM 9, the
appropriate reader number is preceding the error message.
The following table displays possible error messages:
Error code
"00"
"02"
Manual ACM9_ARE i9 release V10.docx
4E
49
54
'N'
'I'
'T'
4B
0D
'K'
<CR>
LRD 01001
LNRD 10001
LERR 10011
LED 1
LRT 30
LPA 00000
23
30
32
'#'
'0'
'2'
Meaning
Unknown instruction
Wrong parameter
0D
<CR>
0D
<CR>
Version: 10
Page: 42 / 51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Are i9Are i9x

Table of Contents