Bosch F.01U.299.030 Operation Manual

Digital discussion system
Table of Contents

Advertisement

Digital Discussion System
CCS 1000 D
en
Operation manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch F.01U.299.030

  • Page 1 Digital Discussion System CCS 1000 D Operation manual...
  • Page 3: Table Of Contents

    Discussion Device 7.3.1 Configure Discussion Device 7.3.2 Initialize Discussion Device 7.3.3 Erase address Web browser interface 7.4.1 First use configuration 7.4.2 Login 7.4.3 Manage discussion 7.4.4 Prepare discussion 7.4.5 Manage recorder Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 4 Maintenance 10.1 Cleaning 10.2 Inspect components 10.3 Storage Technical data 11.1 Control Unit 11.2 Discussion Device 11.3 Extension Unit 11.4 Safety compliance 11.4.1 Control Units 11.4.2 Discussion Devices 11.4.3 Extension Unit 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 5: Safety

    Intentional or unintentional changes or modifications not expressly approved by the party responsible for compliance shall not be made. Any such changes or modifications may void the user’s authority to operate the equipment. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 6: About This Manual

    For information on getting permission for reprints and excerpts, contact Bosch Security Systems B.V.. The content and illustrations are subject to change without prior notice.
  • Page 7: Document History

    Login: added information about first time login. – System info: completed with additional available information about OSS license terms. – Troubleshooting table: updated table with information about how to handle a large amount of API calls Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 8: System Overview

    | System overview Digital Discussion System System overview HD-SDI Figure 3.1: Typical system setup 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 9 12. Coax cable: transports the video signal between the camera and the HD-SDI (13). 13. HD-SDI: is used to connect to the display (8) and to the Ethernet network switch (7). TV- One CORIOmatrix mini and the Kramer MV-6 are supported. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 10: Ccsd-Cu(Rd) Control Unit

    Built‑in loudspeaker and headphone socket with volume control for listening to the ‘floor language’ or recordings. – Additional RCA outputs for individual microphone recording, e.g. for recording individual speakers in a courtroom. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 11: Discussion Device

    Web browser • • • • • • • • • • • • • • • • • • • • • • • Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 12: Planning

    This equipment should be unpacked and handled with care. If an item appears to be damaged, notify the shipper immediately. If any items are missing, notify your Bosch representative. The original packaging is the safest container in which to transport products and can be used to return products for service if necessary.
  • Page 13 Digital Discussion System Planning | en Set of 19” 1U mounting brackets Safety instructions Quick Installation Guide Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 14: Additional Components

    LBB 4116/00 roll of cable. DCN‑DISCLM Cable Clamps (25 pcs) – This cable clamp can be used to secure the connector of a Discussion Device to the next Discussion Device in the daisy chain. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 15 XLR cable - An XLR cable is required if you want to connect an external microphone to the Control Unit. Wireless Access Point (WAP) - A commercially available wireless access point or router is required if you want to connect equipment with a WiFi connection to the system. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 16: Making Custom Extension Cables

    Figure 4.2: Plug and socket pin numbers Figure 4.3: Extension cable connections Signal Color Downlink GND Downlink data Green +24 V(DC) Brown Uplink data White Uplink GND +24 V(DC) Blue Tab. 4.1: Extension cable connections 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 17: Setup Options And Limits

    Control Unit: 40 + 40 = 80 Discussion Devices. Figure 4.4: Example setup for a small/medium sized system (max. 80 discussion devices) Control Unit Extension cable 20 m (66.0 ft) long connected to each trunk of the Control Unit Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 18: Large System (Max. 245 Discussion Devices)

    Limit 6: The maximum cable length for a trunk/tap-off is 100 m (328.0 ft). This includes all extension cables (including the first 20 m (66.0 ft) of extension cable) + the Discussion Device cables of 2 m (6.6 ft) per device. + the Extension Unit cables. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 19 Discussion Devices (245) connected to the system. Figure 4.5: Example setup for a large system (max. 245 Discussion Devices) Control Unit Extension cable 20 m (66.0 ft) long Extension Unit Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 20: Extension Cables

    56 m to 58 m 58 m to 60 m 60 m to 62 m 62 m to 64 m 64 m to 66 m 66 m to 68 m 68 m to 70 m 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 21 82 m to 84 m 84 m to 86 m 86 m to 88 m 88 m to 90 m Tab. 4.2: Max. number of components per trunk/tap-off depending on total length of extension cable(s) Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 22 Extension Units + 29 Discussion Devices = 32 components. Figure 4.6: Example setup for a large system with 35 m of extension cable connected to the trunk and each tap-off Control Unit Extension cable 35 m (115.0 ft) long Extension Unit 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 23: Installation

    – keep the mounting brackets and screws in case you want to install the unit(s) in a rack in the future. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 24: Connections

    If you want to use the web browser interface or system cameras with the CCS 1000 D Digital Discussion System, connect an RJ45 Ethernet cable to the ‘Network’ connector at the rear of the Control Unit. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 25 This allows the system to recover from a power failure. Caution! Non-approved power supplies can damage the equipment. Only use the original Bosch supplied 24 VDC power supply. Bosch Security B.V.
  • Page 26: Control Unit Connections

    Audio input connector for ‘Floor’, i.e. for connecting an external audio source, such as a CD or DVD player. RCA ‘Audio In (2)’ Used with RCA ‘Audio Out (2)’. Audio input connector for either: 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 27 4‑pole circular female connector for connecting the 24 VDC power supply. Caution! Non-approved power supplies can damage the equipment. Only use the original Bosch supplied 24 VDC power supply. Notice! The audio inputs/outputs are mono but the audio connectors allow for the connection of stereo RCA cables.
  • Page 28: Discussion Device Connections

    Trunk connection 6‑pole circular female connector for connecting the next component in the daisy-chain. This can be: – another Discussion Device, – an Extension Unit, or – an extension cable. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 29: Extension Unit Connections

    Power 24V 6A 4‑pole circular female connector for connecting the 24 VDC power supply. Caution! Non-approved power supplies can damage the equipment. Only use the original Bosch supplied 24 VDC power supply. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 30: Configuration

    LED indicator for showing the on/off status. – Red: Power off. – Green: Power on or standby. Note: When the Control Unit is in standby, the Discussion Devices volume control LED (3) flashes slowly. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 31 Red flashing once a second: Recording paused. – Red flashing twice a second: 5 minutes of recording left. Three short beeps, from the monitor loudspeaker, will also be sounded to alert the user. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 32 USB memory stick requirements, see Additional components, page 14 . Headphone socket 3.5 mm (0.14 inch) stereo headphone socket for connecting (CCSD‑CURD only) headphones (for listening to recorded discussions). When headphones are connected, the built‑in loudspeaker is muted. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 33: Discussion Modes

    The speakers list can be (viewed and) managed in the web browser interface. The waiting list is not used in this mode. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 34: Key Combinations

    Resets all system settings and values to the factory defaults. Notice! When the system is reset to the factory defaults, the latest version of the software that the system was upgraded to will be maintained. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 35: Extension Unit

    The Extension Unit is switched on and off automatically with the Control Unit. Number Item Description Power on/off LED LED indicator for showing the on/off status – Red: Power off or standby. – Green: Power on. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 36: Discussion Device

    Wait until all LEDs on the device are off. The device is then correctly initialized. If the device does not initialize correctly, erase the address as described in Erase address, page 37 , and then push the microphone button to initialize/address the device 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 37: Erase Address

    The LED indicator above the microphone button is lit amber. Initialize the device as described in Initialize Discussion Device, page 36 . Figure 7.4: Base view Concealed initialization button. Slide‑switch for configuring. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 38: Web Browser Interface

    – On a Windows PC/laptop, make sure: – Bosch DNS‑SD is installed. Bosch DNS‑SD is on the DVD supplied with the Control Unit and can be downloaded from the relevant product page on: www.boschsecurity.com – a dynamic IP address has been assigned to the laptop/PC. If the laptop/PC has a static IP address, the web browser interface will not work correctly.
  • Page 39: Login

    The default language is the language of the operating system running the browser. – if the default language is not available, English is automatically selected. If the login is successful, the homepage is displayed: Figure 7.5: Homepage (CCSD‑CURD) Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 40 | Configuration Digital Discussion System Notice! Some web browser interface options may not be available for the CCSD‑CU, because this version of the Control Unit does not have DAFS and recording functionality. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 41 Control Unit and web browser interface application. See System info, page 52 . System info Exits the discussion application and returns you to None the login page. See Logout, page 52 . Logout Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 42 Click the ‘stop recording’ button to stop Manage meeting recording. Stop recording (CCSD‑CURD only) Opens the master volume control slider. Controls Configure or Manage the discussion devices loudspeaker and Control meeting Unit audio output level. Master volume 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 43: Manage Discussion

    Recording and playing back discussion, page 54 . – Master volume control Click the master volume control button to adjust the audio output level of the Discussion Devices and Control Unit. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 44: Prepare Discussion

    Discussion Device priority button is used. – Stop all speakers and remove all waiting participants: When selected all speakers and requests are cancelled when the Discussion Device priority button is used. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 45: Manage Recorder

    Recycle bin button (Only visible when a file is selected): Deletes the selected file from the used memory and overview. Note: For more information on recording and playing back audio files, refer to Recording and playing back discussion, page 54 . Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 46: System Settings

    Configure: This right gives access to the system settings page (excluding the users page, unless the user has the right ‘modify users’), the system info and logging pages, and volume control. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 47 SDI Switcher: Enter the IP address of the HD‑SDI video switcher. Do not use leading zeros. If leading zeros are entered, the CCS 1000 D Digital Discussion System will not be able to control the switcher. Example: – Correct IP address: 192.168.10.111 Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 48 Note: Only possible if your PC/laptop or tablet device is connected via the wired Ethernet connection of the system. Notice! Ensure that the Bosch ONVIF Camera has firmware 5.80 or higher. ONVIF cameras ONVIF cameras are automatically detected, but you still need to: Enter a username and password if the camera has a username and password configured.
  • Page 49 LED indicator above the microphone button flashes. Note: This is only possible when the Selection mode checkbox at the left bottom of the page is selected. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 50 Click the Date and time button to open the date and time settings page. Click the Change date and time settings button to select: – Time: Select the local time. – Date: Select the current date. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 51 Exit the upgrade page after completion of the upload process (‘done’state). Clear the browser cache (history), so that the new functionality is displayed in the web browser. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 52: Power

    Link to download the Open Source Software license terms System info is used by a technician. 7.4.10 Logout Click the Logout button on the homepage to log out from the discussion application. The login page is displayed. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 53: Restful Application Program Interface (Api)

    This function gives the possibility to retrieve and set microphone sensitivity of an individual device. The sensitivity range is from -6dB to +9dB. For more information on the Application Program Interface, refer to the API manual, which can be downloaded at: https://licensing.boschsecurity.com/software Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 54: Operation

    Under the detected drive for the Control Unit, create a txt file called ‘no-file-split’. Remove the file extension “.txt.” To reset recorded files to a maximum duration of 60 minutes, delete the ‘no-file-split’ file. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 55 Download the MP3 file(s) from the internal memory of the Control Unit to a PC, by using the micro USB connector at the rear of the Control Unit. Notice! Recordings cannot take place when the Control Unit is connected to a PC with the micro USB connector. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 56: Using The Microphone Button

    As soon as the active speaker disables their microphone button you will be allowed to speak. – Your microphone is active; you are allowed to speak. All LEDS off – The device is off. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 57: Using The Priority Button

    (2) is used to activate and deactivate the microphone as required. Adjusting headphones volume Figure 8.4: Device with chairperson‘s button fitted Use the rotary thumbwheel (3) on the side of the device to adjust the volume of the headphones, when connected. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 58: Troubleshooting

    Decrease the volume of the Control Unit loudspeaker. – Increase the distance between the Discussion Devices and/or the Control Unit. – Increase the distance between the headphone and the microphone of a 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 59 Recording to the internal Internal memory full or USB – Check internal recording memory not possible. connected. LED indicator: Red/green flashing indicates that the internal memory is full. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 60 USB memory stick damaged. – Check the read/write possibilities of the USB stick. – Note: If the Control Unit does not detect the USB memory stick, it will 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 61 – For the Kramer MV‑6 switcher, set the TCP connection port number to 5000. – For the tvOne CORIOmatrix switcher, set the TCP connection port number to 10001. Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 62: Maintenance

    10.2 Inspect components Check all CCS 1000 D Digital Discussion System components for signs of wear and tear. Replacement Discussion Devices can be ordered from your Bosch representative, if required. Check all connectors and system cabling for damage. Check the Discussion Device microphone buttons for correct operation. The buttons should not be loose or remain pressed in when operated.
  • Page 63: Technical Data

    -56 dBV XLR maximum microphone input -26 dBV RCA nominal input -24 dBV (+/- 6 dB) RCA maximum input +6 dBV > 93 dBA Frequency response 30 Hz to 20 kHz <0.1% Audio outputs RCA nominal output -24 dBV (+6/- 24 dB) Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 64: Discussion Device

    64 x 203 x 146 mm (H x W x D) (2.5 x 8.0 x 5.7 in) Height with microphone in horizontal position 130 mm (5.1 in) Length of microphone from mounting surface CCSD‑DS: 310 mm (12.2 in) CCSD‑DL: 480 mm (18.9 in) Weight Approx. 1 kg (2.2 lb) 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 65 Pearl light grey (RAL 9022) matt-gloss Environmental Operating temperature 0 ºC to +35 ºC (+32 ºF to +95 ºF) Storage and transport temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity 5% to 98% non-condensing Air pressure 600 to 1100 hPa Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 66: Extension Unit

    Pearl light grey (RAL 9022) matt-gloss Environmental Operating temperature 5 ºC to +45 ºC (+41 ºF to +113 ºF) Storage and transport temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity 5% to 98% non-condensing 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 67: Safety Compliance

    Only applicable for the power adaptor. 11.4.2 Discussion Devices CE, WEEE ICES-003 AU/NZ RU/KZ/BY China RoHS SASO 11.4.3 Extension Unit CE, WEEE UL, FCC CSA, ICES-003, EPS KCC, KC , K-MEPS Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 68 | Technical data Digital Discussion System AU/NZ RCM, MEPS RU/KZ/BY China RoHS, CCC BSMI SASO Note: Only applicable for the power adaptor. 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 69 Digital Discussion System Technical data | Bosch Security B.V. Operation manual 2020.05 | V2.2 |...
  • Page 70 | Technical data Digital Discussion System 2020.05 | V2.2 | Operation manual Bosch Security B.V.
  • Page 72 Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V., 2020 202009021335...

This manual is also suitable for:

Ccs 1000 d

Table of Contents