Troubleshooting

If you find any faults not listed here, please Call Buffalo agent or qualified technician.
Fault
Power indicator (red LED)
remains inactive
Unit is very noisy during
operation
Power indicator (red LED)
flashes and an acoustic
signal sounds
Power indicator (red
LED) and filter indicator
(green LED) flash and an
acoustic signal sounds
Appliance doesn't start
Line fuse / Ground fault
circuit fuse (GFCI) blow-
out
Low filtration
performance
Oil splashed sideways
and / or at the back of
the pump-filter unit
Power and filter indicators
flash 10 seconds after
plugging in and an
acoustic signal sounds
Gap between control unit
and pump-filter unit
8
CU489_EN_A5_v1_20230414.indb 8
CU489_EN_A5_v1_20230414.indb 8
Probable Cause
Power cord not plugged in
Power cord defective
Device defective
Star handles are loose
Rotor defective
Rotor scratches on the fryer
Over-temperature
Appliance is at an angle of
more than 17°
Strong vibrations
Control unit defective
Power cord or other electrical
components defective
Rotor defective / blocked
Circuit overloaded
Particle filter is full
Pump-filter unit clogged
Filter paper not inserted
properly
Motor defective
Particle filter full
Too much space between
filter cover and pump-filter
unit
Filter paper not inserted
overlapping
Start / Stop button defective
Control unit wet inside
Filter cover not closed
properly
Filter cover or pump-filter
unit bent
Solution
Plug in the appliance
Call Buffalo agent or qualified
technician
Call Buffalo agent or qualified
technician
Tighten star handles
Call Buffalo agent or qualified
technician
Change the position of the appliance
in the deep fryer
Let the appliance cool down.
Place the appliance in a cool place
Check position of the appliance in the
fryer
Please contact service
Damaged rotating parts
Filter cover not closed properly
Call Buffalo agent or qualified
technician
Call Buffalo agent or qualified
technician
Call Buffalo agent or qualified
technician
Change socket/circuit
Change particle filter
Empty pump-filter unit
Boil out to remove heavy dirt
Insert filter as described
Call Buffalo agent or qualified
technician
Change particle filter
Please contact service
Insert particle filter as described
Call Buffalo agent or qualified
technician
Please let it dry
Close the filter cover properly and
snap it into the pump-filter unit
Call Buffalo agent or qualified
technician