SERIES 3000 MKIII TECHNICAL MANUAL

17. General specifications

Series 3000 MkIII Detector
Use
Rugged and reliable gas detector for the protection of personnel from toxic and oxygen gas hazards. Suitable for intrinsically
safe installation and use in Zone 0 or 1 or 2 or 20 or 21 or 22 hazardous areas in Europe, and hazardous locations Class I,
Divisions 1 & 2, Groups A, B, C & D; Class II, Divisions 1 & 2, Groups E, F & G application in North America.
Detectable Gases & Performance (See notes below)
Selectable Full
Gas
Scale Range
Oxygen
25.0%/Vol only
Hydrogen Sulfide
10.0 to 50.0ppm
Hydrogen Sulfide
50 to 500ppm
Carbon Monoxide
100 to 500ppm
Sulfur Dioxide
5.0 to 20.0ppm
Ammonia
50 to 200ppm
Ammonia
200 to 1,000ppm 1,000ppm
Chlorine
5.0 to 20.0ppm
Chlorine Dioxide
1.00ppm only
Nitric Oxide
100ppm only
Nitrogen Dioxide
5.0 to 50.0ppm
Hydrogen
1,000ppm only
Hydrogen
9,999ppm only
Hydrogen Chloride
10.0 to 20.0ppm
Hydrogen Cyanide
30.0ppm only
Hydrogen Fluoride
12.0ppm only
Ozone
0.400ppm only
Phosphine
1.2ppm only
Fluorine
4.00ppm only
Ethylene Oxide
20.0 to 50.0ppm
Electrical
2 wire loop powered
Connections and
10Vdc(±10%) to 30Vdc (max)
Power
22mA max. overrange
Maximum Power
Less than 1.2 W
Consumption
Barrier Requirements
Ca (or Co) > Ci+C, La (or Lo) > Li+L, Voc < Vmax = 30 V, Isc < Imax = 125 mA
2 wire with screen (90% coverage) or conduit.
Recommended Cable
0.5mm
0-100% FSD 4-20mA
Max. overrange 22mA
Signal
Inhibit = Selectable 3mA (fault) or 4mA for toxic sensors or 3mA (fault) or 17.4mA for oxygen sensors.
Fault = 3mA
Construction
Material
Transmitter: Epoxy painted aluminium alloy LM25 or 316 Stainless Steel. Sensor: 316 Stainless Steel with PTFE filter
Entries
2 x M20 (for ATEX/IECEx Approval) or 2 x 3/4NPT (for UL Approval)
164 x 201 x 99mm
Maximum Dimensions
6.4 x 7.9 x 3.9 inches
Weight
Aluminium alloy LM25 : 1.7kg (3.75lbs.), Stainless Steel 316: 3.7kg (8.16lbs.)
Environmental
IP Rating
IP66 (EN 60529). NEMA 4X (Not tested by UL but by another Third Party Laboratory).
Certified Operating
ATEX/IECEX: -40°C to +55°C (-40°F to +131°F)
Temperature
UL/cUL: -40°C to +55°C (-40°F to +131°F)
Continuous 20-90%RH (non condensing)
Operating Humidity
Intermittent 0-99%RH (non condensing)
Operating Pressure
90-110kPa
Transmitter:-40°C to +55°C (-40°F to +131°F) 30-70% RH (non condensing)
Storage Conditions
To ensure the optimum operational life of electrochemical cell sensors, replacement cells should be stored in sealed packaging
in cool dry conditions and preferably kept refrigerated at temperatures between 0 and 20 degrees C.
Transmitter: UL/cUL Class I, Divisions 1 & 2, Groups A, B, C & D; Class II, Divisions 1 & 2, Groups E, F & G
Remote Sensor Accessory: UL/c-UL = Class I, Div. 1, Groups A, B, C & D; Class II Division 1 & 2, Groups E, F & G; Class 1,
Zone 0, Group IIC; Class II, Zone 20
Certification
Transmitter: ATEX:
Remote Sensor Accessory: ATEX
Transmitter: IECEx UL 11.0010X Ex ia IIC T4 Ga Ex ia IIIC T135
Remote Sensor Accessory: IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135
CE compliant in accordance with:
Approvals
ATEX Directive 94/9/EC
EMC Directive 2004/108/EC (EN50270:2006)
Notes: Detection performance is temperature and humidity dependent. Listed data is based at 20°C, 50% RH only. Response time is
longer when operating in colder temperatures.
*When operating in Hazardous Area applications the detector must not be operated outside the certified temperature range. See
Certification details for UL, c-UL and ATEX/IECEx certified temperature ranges.
Default
Selectable Cal
Steps
Range
Gas Range
25.0%VOL
n/a
20.9%/Vol (Fixed) 20.9%/Vol
15.0ppm
0.1ppm
100ppm
10ppm
300ppm
100ppm
15.0ppm
5.0ppm
200ppm
50ppm
50ppm
5.0ppm
5.0ppm
1.00ppm
n/a
30 to 70% of
100ppm
n/a
10ppm
5.0ppm
selected full
1,000ppm
n/a
scale range
9,999ppm
n/a
10ppm
1.0ppm
30.0ppm
n/a
12.0ppm
n/a
0.400ppm
n/a
1.2ppm
n/a
4.00ppm
n/a
25.0ppm
5.0ppm
(20AWG) to 2.0mm
(14AWG) Max.
2
2
II 1 (1) GD Ex ia IIC T4 Ga Ex ia IIIC T135
II 1 GD Ex ia IIC T4 Ga Ex ia IIIC T135
Response
Accuracy
Default
Time
(ppm or % of
Cal Point
(T90)
applied gas)
secs
15
+/-0.5% O2
10ppm
30
+/-0.3 or +/-20%
50ppm
30
+/-2 or +/-20%
100ppm
30
+/-2 or +/-20%
5.0ppm
40
+/-0.3 or +/-20%
100ppm
180
+/-10 or +/-20%
300ppm
180
+/-15 or +/-20%
2.0ppm
90
+/-0.3 or +/-20%
0.5ppm
120
+/-30%
50ppm
50
+/-3 or +/-20%
5ppm
60
+/-3 or +/-20%
500ppm
90
+/-10 or +/-25%
5000ppm
90
+/-25 or +/-30%
5.0ppm
150
+/-1 or +/-20%
10.0ppm
200
+/-1.0ppm or +/-30%
5.0ppm
300
+/-30%
0.200ppm
60
+/-0.020ppm or
+/-30%
0.5ppm
33
+/-0.03 or +/-20%
2.00ppm
35
+/-0.3ppm or +/-20%
10.0ppm
125
+/-1.5ppm or +/-20%
o
C Da
o
C Da
o
C Da
o
C Da
+55C intermittent
1
35
MAN0917_Issue 6_08/2015
Operating Temperature*
Drift over
time
Min
Max
<4%/yr
-30°C / -22°F 55°C / 131°F
<0.5ppm/
-40°C / -40°F 55°C / 131°F
yr
<0.5ppm/
-40°C / -40°F 55°C / 131°F
yr
<2ppm/yr -40°C / -40°F 55°C / 131°F
<2%/mo
-40°C / -40°F 55°C / 131°F
<5%/6 mo -20°C / -4°F
40°C / 104°F
<5%/6 mo -20°C / -4°F
40°C / 104°F
<2ppm/yr -10°C / 14°F
55°C / 131°F
<5%/yr
-20°C / -4°F
55°C / 131°F
<2%/mo
-20°C / -4°F
55°C / 131°F
<2%/mo
-20°C / -4°F
55°C / 131°F
<2%/mo
-20°C / -4°F
55°C / 131°F
<10%/6
-20°C / -4°F
55°C / 131°F
mo
<20%/yr
-20°C / -4°F
40°C / 104°F
<2%/mo
-20°C / -4°F
55°C / 131°F
<20%/yr
-20°C / -4°F
55°C / 131°F
<5%/mo
-20°C / -4°F
55°C / 131°F
<10%/yr
-20°C / -4°F
40°C / 104°F
<10%/yr
-20°C / -4°F
55°C / 131°F
<5%/yr
-20°C / -4°F
55°C / 131°F