Operation; Shut-Off Procedure - Honeywell RV8310D Installation Instructions Manual

Millivolt receiver/modulating gas valve
Table of Contents

Advertisement

OPERATION

1. Turn the gas control knob counterclockwise from
OFF to the PILOT position.
2. Push the knob down and hold in position. The pilot
valve opens and allows gas to flow to the pilot
burner.
3. Push the plunger on the piezo until the pilot burner
is lit. When the pilot burner is lit, the LED on
the control will come on after approximately
60 seconds and will blink continuously.
4. Release the gas control knob. The shaft moves
upward and the pilot burner stays burning. If the
pilot burner goes out, repeat steps 2 and 3.
5. Turn the gas control knob counterclockwise to the
ON position. If the manual switch is in the LOCAL
position, the main burner will turn on immediately.
On the initial use of a transmitter, a recognition operation
is required between the receiver/valve and the
transmitter.
1
L1
OUTLET
(HOT)
PRESSURE
TAP
L2
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

Shut-Off Procedure

If the manual switch is in the REMOTE position, the
RT8220A transmitter can shut off the main burner and
fan. However, the control is still on and a command from
the transmitter can turn on the main burner and fan.
To shut off the system:
Turn the gas control knob clockwise to the OFF position.
This closes the main gas and safety valves. The
transmitter cannot turn on the main burner or the fan.
FAN
INLET
PRESSURE
TAP
GAS CONTROL KNOB
Fig. 8. Millivolt system wiring diagram.
RV8310D,E MILLIVOLT RECEIVER/ MODULATING GAS VALVE
WARNING
Fire Hazard.
Can cause severe injury or death.
Moving the LOCAL/REMOTE switch can cause
the main burner to come on immediately. Stand
away from the main burner when moving the
LOCAL/REMOTE switch.
1. Turn the gas control knob to the PILOT position.
2. Move the LOCAL/REMOTE switch to the LOCAL
position for at least two seconds; then move the
switch to the REMOTE position.
3. Press the FAN or FLAME button on the transmitter
within 30 seconds of the switch change.
4. Turn the gas control knob to the ON position.
The LED will blink indicating that the transmitter will now
work with the receiver/valve. If the switch stays in the
REMOTE position, the RT8220A Transmitter will control
the main valve, flame modulation level and fan control.
If the LOCAL/REMOTE switch is in the LOCAL position,
the receiver/valve will be at the highest fixed pressure
setting.
PIEZO
LED
PILOT ADJUSTMENT
SCREW
5
BURNER
PILOT
BURNER
ASSEMBLY
PILOT TUBE
THERMOPILE
LEADWIRE
THERMOPILE LEADWIRE
M16682
66-1106—2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rv8310e

Table of Contents