Millivolt receiver/modulating gas valve
Table of Contents

Advertisement

OUTLET
PRESSURE
TAP
WIRING
Follow the wiring instructions furnished by the appliance
manufacturer, if available, or use the general instructions
provided below. Where these instructions differ from
the appliance manufacturer, follow the appliance
manufacturer instructions. For a typical wiring diagram,
see Fig. 5.
WARNING
Electrical Shock Hazard.
Can cause serious injury or death.
Disconnect power supply before making wiring
connections. More than one disconnect can be
involved.
MOTOR
COVER
MOTOR
WRENCH BOSS
M16681A
Fig. 3. Top view of gas valve.
Fig. 4. Proper use of wrench on gas valve.
RV8310D,E MILLIVOLT RECEIVER/ MODULATING GAS VALVE
INLET
WIRING
PRESSURE
PIEZO
TERMINALS
TAP
LP
LED
PILOT
ADJUSTMENT
GAS CONTROL KNOB
SCREW
All wiring must comply with applicable electrical codes
and ordinances.
1. Disconnect power supply before making wiring
connections to prevent electrical shock or
equipment damage.
2. Connect white leads of thermopile to terminals with
white dots.
NOTE: This valve can be used only in a self-generating
power system.
3
FUEL CONVERSION
PLUG
M17501