Fuel Conversion; Converting To Lp Gas; Converting To Natural Gas - Honeywell RV8310D Installation Instructions Manual

Millivolt receiver/modulating gas valve
Table of Contents

Advertisement

RV8310D,E MILLIVOLT RECEIVER/ MODULATING GAS VALVE

FUEL CONVERSION

The RV8310D Millivolt Receiver/Modulating Gas Valve is
not convertible between natural gas and LP.
The RV8310E Millivolt Receiver/Modulating Gas Valve is
convertible between natural gas and LP. Conversion kits
are available for this purpose.
The 396206-1 Natural Gas Conversion Kit changes the
RV8310E from regulated LP gas to regulated natural
gas. The 396206-2 LP Conversion Kit changes the
RV8310E from regulated natural gas to regulated LP
gas. Kits include a fuel conversion plug (blue for natural
gas, red for LP gas) and a conversion label.
WARNING
Fire or Explosion Hazard.
Can cause serious injury, death or property
damage.
Turn off the gas supply at the appliance service
valve before beginning conversion.
MOTOR
COVER
MOTOR
OUTLET
INLET
PRESSURE
PRESSURE
TAP
TAP
WRENCH
GAS
BOSS
CONTROL
KNOB
M17775A
Fig. 5. RV8310E top view, showing motor cover
and conversion plug location.
Fig. 6. Gas selector switch under motor cover.
66-1106—2
PIEZO
WIRING
TERMINALS
LED
NG
PILOT
CONVERSION PLUG
ADJUSTMENT
(NATURAL GAS
SCREW
PLUG SHOWN)
RED SCREW
(LP)
BLUE SCREW
(NATURAL GAS)
L A B
E L
Fig. 7. Insertion of LP or Natural Gas

Converting to LP Gas

1. Turn off gas supply at the appliance service valve.
2. Remove cover from motor, exposing the gas
selector.
3. Using a standard screwdriver, push the gas
selector down and rotate until the arrows point to
the red-colored screw.
4. Insert the LP Fuel Conversion Plug (red).
5. Attach the LP conversion label to the valve.
6. Replace cover on the motor.

Converting to Natural Gas

1. Turn off gas supply at the appliance service valve.
2. Remove cover from motor, exposing the gas
selector.
3. Using a standard screwdriver, push the gas
selector down and rotate until the arrows point to
the blue-colored screw.
4. Insert the Natural Gas Fuel Conversion Plug
(blue).
5. Attach the Natural Gas conversion label to the
valve.
6. Replace cover on the motor.
NOTE: The high and low outlet pressure settings for
natural gas and LP cannot be changed.
S
N G
N I
A R
W
M17900A
4
OR
PINS
M17774
conversion plug.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rv8310e

Table of Contents