GE Contactless
Reader
Models 240/245/250
Installation Guide
GE Security, Inc.
791 Park of Commerce Boulevard
Suite 100
Boca Raton, Florida 33487
(561) 998-6100
Part Number: 460563001C
February, 2004

Advertisement

Table of Contents
loading

Summary of Contents for GE Security 240

  • Page 1 GE Contactless Reader Models 240/245/250 Installation Guide GE Security, Inc. 791 Park of Commerce Boulevard Suite 100 Boca Raton, Florida 33487 (561) 998-6100 Part Number: 460563001C February, 2004...
  • Page 2 This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Industrial Systems. GE PROVIDES THE FOLLOWING DOCUMENT AND THE INFORMATION INCLUDED THEREIN AS IS AND WITHOUT...
  • Page 3: Table Of Contents

    Keypad Operation: Model 245............10 Wiring....................11 Installation Notes: Model 24x/250..........12 Point-to-Point Wiring Diagrams............13 Troubleshooting ....................19 Technical Specifications (24x)................ 23 Technical Specifications (250)................ 25 Regulatory Notices..................27 UL......................27 FCC ...................... 27 Regulatory Notices:..................29 GE Contactless Reader Model 24x/250...
  • Page 4 GE Model 24x Reader Backplate (includes tamper switch magnet) ........3 Figure 5: Isolation Spacer ............. 4 Figure 6: GE Model 24x Backplate and Snap-on cover ....7 Figure 7: Back-to-Back/Center-to-Center Installation....8 Figure 8: Mounting the GE Model 250 .......... 9...
  • Page 5: Introduction

    Introduction The GE Contactless Model 240, 245, and 250 readers read ISO 14443A and ISO 15693 compliant badges, disc tags, and key fobs. The Model 245 includes an integral 12-button (3x4) keypad for PIN entry. FIGURE 1: GE Contactless Reader Model 240...
  • Page 6: Figure 3: Ge Contactless Reader Model 250 (Mullion Enclosure)

    FIGURE 3: GE Contactless Reader Model 250 (Mullion Enclosure) GE Contactless Reader Model 24x/250...
  • Page 7: Figure 4: Ge Model 24X Reader Backplate (Includes Tamper Switch Magnet)

    FIGURE 4: GE Model 24x Reader Backplate (includes tamper switch magnet) Notes: • Mounting holes fit standard US single-width electrical box and standard European (EMEA) electrical box hole pattern. • For flush mounting, a cutout in the mounting surface, to accommodate the connector, must be made.
  • Page 8: Figure 5: Isolation Spacer

    FIGURE 5: Isolation Spacer GE Contactless Reader Model 24x/250...
  • Page 9: Product Overview

    Secure Perfect 5.0 supports badge IDs (BIDs) to a maximum of 20 digits. Secure Perfect 4.0 supports badge IDs (BIDs) to a maximum of 12 digits. Since the Model 24x Contactless Reader outputs a 16-digit number, the Secure Perfect 4.0 microcontrollers must be configured to receive the GE Contactless Reader Model 24x/250...
  • Page 10 If you are using Model 240/245/250 readers with your Secure Perfect system (4.0), you cannot combine with any other reader or credential technologies. To make your Secure Perfect 4.0 system compatible with GE Models 240/ 245/250 Contactless readers, do the following: Install Secure Perfect 4.0 as instructed.
  • Page 11: Installation

    Installation FIGURE 6: GE Model 24x Backplate and Snap-on cover The front cover snaps into place. To remove the cover, use a small flat- blade screwdriver to pry the cover from the backplate, using either of the two provided locations on the vertical sides of the reader.
  • Page 12: Installation Considerations

    Installation Considerations Installation of the GE Model 24x Reader on metal. For the Model 24x readers, read-range reduction can be improved by adding Isolation Spacers (approximately 25% per plate) up to a maximum of four spacers. Installation of two Model 24x/250 readers side-by-side and back-to- back.
  • Page 13: Figure 8: Mounting The Ge Model 250

    (101.60 mm) or less, a metal plate (for example: Reader isolation plate, metal wall) must be placed between the readers. To obtain the maximum read range, mount each GE Model 24x/250 reader onto one or more Isolation Spacers.
  • Page 14: Micro Compatibility

    Micro Compatibility • Micro/5 Controller with either 2RP or 8RP Reader Boards: refer to the Micro/5 Installation Guide. IMPORTANT: DO NOT use the GE Model 24x/250 readers with the Micro/5 2SRP. • Micro/PX-2000 and Micro/PXN-2000 controllers: refer to the Micro/ PX-2000 and Micro/PXN-2000 Installation Guide.
  • Page 15: Wiring

    Exit request (REX) Green LED Micro control, red LED (option) Reserved for future use Reserved for future use (model 250 only) Reserved for future use (model 250 only) Reserved for future use (model 250 only) GE Contactless Reader Model 24x/250...
  • Page 16: Installation Notes: Model 24X/250

    Current limiting may be achieved by using either a current-limiting power supply or by wiring in an external fuse. J3 is typically not used in this installation. See Figure 12, “GE Model 24x/250 Reader to Micro/Reader Junction Box (Manufactured prior to February 15, 2004) and Microcontroller,”...
  • Page 17: Point-To-Point Wiring Diagrams

    Point-to-Point Wiring Diagrams FIGURE 9: GE Model 24x/250 Reader Wiring Diagram to Micro/5 8RP GE Contactless Reader Model 24x/250...
  • Page 18 Readers 9 - 16 Note: The 8RP board appears to the Microcontroller as four 2RP boards. SW 2 Board Type Standard Board 1 Board 2 a. Readers 1 - 8. b. Readers 9 -16. GE Contactless Reader Model 24x/250...
  • Page 19: Figure 10: Ge Model 24X/250 Reader To 2Rp

    FIGURE 10: GE Model 24x/250 Reader to 2RP GE Contactless Reader Model 24x/250...
  • Page 20 Table 6: 2RP Reader Board Address Settings SW 1 SW 2 Reader Board Note: Switches SW2-5, 6, 7, and 8 are not used. Jumper W1 RN2 and RN5 (labeling) Use 2k Ω (202) resistor packs. Set to 12 V GE Contactless Reader Model 24x/250...
  • Page 21: Figure 11: Ge Model 24X/250 Reader To Micro/Reader Junction Box (Manufactured After February 15, 2004) And Microcontroller

    FIGURE 11: GE Model 24x/250 Reader to Micro/Reader Junction Box (Manufactured after February 15, 2004) and Microcontroller When using a Micro/Reader Junction Box relay as a dry contact, place a jumper across J4, pins 1 and 2 as shown in Figure 11 above. Connect the power supply in series with the door strike.
  • Page 22: Figure 12: Ge Model 24X/250 Reader To Micro/Reader Junction Box (Manufactured Prior To February 15, 2004) And Microcontroller

    FIGURE 12: GE Model 24x/250 Reader to Micro/Reader Junction Box (Manufactured prior to February 15, 2004) and Microcontroller When using a Micro/Reader Junction Box relay as a dry contact, place a jumper across J4, pins 1 and 2 as shown in Figure 12 above. Connect the power supply in series with the door strike.
  • Page 23: Troubleshooting

    LED does not light when an Verify that the access card has been entered and ISO 15963 or that the reader has been properly configured in ISO 14443A card the host system. is presented. GE Contactless Reader Model 24x/250...
  • Page 24 If none of the above steps have identified the problem, there may be a significant noise source present in the installation which is interfering with the reader-to-microcontroller communications. If this is the case, use shielded wire for reader-to- microcontroller connections. GE Contactless Reader Model 24x/250...
  • Page 25 1uf, 250V capacitor on the circuit side (backside) of the board, near connector J6. The capacitor should be wired to pins 1 and 4 on J6. Refer to Figure 13, “Power Comm Board with Capacitor,” on page 22 GE Contactless Reader Model 24x/250...
  • Page 26: Figure 13: Power Comm Board With Capacitor

    FIGURE 13: Power Comm Board with Capacitor GE Contactless Reader Model 24x/250...
  • Page 27: Technical Specifications (24X)

    (261 m) (952 m) (399 m) Note: With the exception of the Power, Common/Ground, Reader Data Lines and External Green LED Circuit, all other wiring is limited to same-room installations or no more than 20 feet. GE Contactless Reader Model 24x/250...
  • Page 28 ISO 15693 and ISO 14443A Standards Microcontroller Micro/5-PX and Micro/5-PXN with 2RP and compatibility 8RP processor boards (incompatible with M/5 and 2SRP board configurations) Micro/PX-2000 and Micro/PXN-2000 Status Indicators Red, Yellow, and Green LEDs and Beeper GE Contactless Reader Model 24x/250...
  • Page 29: Technical Specifications (250)

    Distance 856 ft. (261 m) Note: With the exception of the Power, Common/Ground, Reader Data Lines and External Green LED Circuit, all other wiring is limited to same-room installations or no more than 20 feet. GE Contactless Reader Model 24x/250...
  • Page 30 ISO 15693 and ISO 14443A Standards Microcontroller Micro/5-PX and Micro/5-PXN with 2RP and compatibility 8RP processor boards (incompatible with M/5 and 2SRP board configurations) Micro/PX-2000 and Micro/PXN-2000 Status Indicators Red, Yellow, and Green LEDs and Beeper GE Contactless Reader Model 24x/250...
  • Page 31: Regulatory Notices

    Micro/5 2RP; with the Micro/5 8RP reader processor boards nor with Micro/PX-2000 and Micro/PXN-2000 controllers. Only the SF2F protocol was verified by UL. Changes or modifications not expressly approved by GE Security for compliance could void the user’s authority to operate the equipment. FCC and CE Compliance.
  • Page 32: Figure 14: Stripping Of Shield Grounds

    FIGURE 14: Stripping of Shield Grounds GE Contactless Reader Model 24x/250...
  • Page 33: Regulatory Notices

    We declare under our sole responsibility that this product is in conformity with Directive 93/68/EEC (Marking) and/or complies with the essential requirements and all other relevant provisions of the 1999/5/EC (R&TTE) based on test results using harmonized standards in accordance with the Directives mentioned. GE Contactless Reader Model 24x/250...
  • Page 34 NOTES GE Contactless Reader Model 24x/250...