Module Function; Front-Panel Indicators, Connections, And Adjustments; Figure 3-2 Cim Connectors; Table 3-1 Cim Panel Connectors And Push Button - Cisco ONS 15200 Handbook

Table of Contents

Advertisement

Functional Description

3.1.1 Module Function

The CIM can extend the controller area network (CAN) bus of the ONS 15252 MCU to another MCU
or to an ONS 15201 SCU. This arrangement allows several network elements (NEs) to work together as
a larger functional unit.
The CIM is also the interface to the Maintenance Manager (MM) software package. This interface makes
any PC equipped with required hardware a platform for ONS 15200 system surveillance,
troubleshooting, and maintenance. A EIA/TIA–232 (NONE standard) port (Tx, Rx, Ground) is available
on the CIM, which is accessible with an additional CIM adapter cable.
The CIM is active, but does not include alarm or supervisory subunit functions.
Note

3.1.2 Front-Panel Indicators, Connections, and Adjustments

Figure 3-2
Table 3-1
Table 3-1
Connector
INT BUS
MA
ACO (Push Button)
Figure 3-2
Three LEDs show NCB module signals on the front of the CIM
Cisco ONS 15200 Module Handbook
3-2
shows the position of the LEDs, the push button, and the connectors, which are described in
and
Table
3-2.
CIM Panel Connectors and Push Button
Significance
Internal Bus (CAN Bus)
(6-pole modular jack)
Management Access (8-pole modular jack)
Alarm Cut Off
CIM connectors
Internal Bus
Management
Access
Chapter 3
Communication Interface Module
(Table
3-2).