Precautions In Case Of Long Idle Periods; Gtroubleshooting; Anomaly Table - Electrolux SkyLine ChillS 202 User Manual

Lengthwise blast chillers/freezers
Table of Contents

Advertisement

• Drain plug
To clean the drain plug, remove it as shown in the figure
below:
a
Clean it with lukewarm water and neutral soap, then rinse and
dry thoroughly.
• Other surfaces
Clean metal and plastic parts only with non-aggressive
detergents. Stop immediately using those products if
G
TROUBLESHOOTING
G.1

Anomaly table

In case of anomaly, the appliance always displays a warning message or alarm describing the occurring fault. The corresponding icon
remain visible until the problem is resolved.
Warnings icon
!
Alarms signalling icon
Follow the indications given by the appliance and, if required, contact the Customer Care Service remembering to:
1. disconnect the appliance from the main power supply;
2. switch off the safety circuit breaker ahead of the appliance;
In some cases, faults can be eliminated easily and quickly by following the indication of this troubleshooting guide:
TYPE OF
CODE
ANOMALY
swcTTm
INFO
ALARM
ECoM
Stops Machine
ALARM
PFAC
Stops Machine
ALARM
PdEF
Resetting
Machine
46
b
c
DESCRIPTION
POSSIBLE CAUSES
Give information
about switching
Food probe not inserted in food
operations from
probe to time
Communication
• Internal error -Electronic boards
error between
disconnected
boards
• Electronic board failure
Memorized
parameters
Software corruption
corrupted.
Memorized
default parame-
Software corruption
ters corrupted
detecting any visual or tactile characteristic change on
surfaces and thoroughly rinse with water (examples: plastic
discoloring/melting/other, or metal showing rust/stains/
scratches). Carefully dry after rinsing.
F.1.4

Precautions in case of long idle periods

If the appliance is not going to be used for some time, take the
following precautions:
• disconnect the power supply;
• remove all food from the compartment and clean the inside
and accessories;
• clean the cabinet, going over all the stainless steel surfaces
vigorously with a rag moistened with paraffin oil to create a
protective film;
• leave the door or the drawers open so that air can circulate
inside, preventing the formation of unpleasant odours.
• periodically air the premises.
After carrying out maintenance make sure the appliance is able
to work safely and, in particular, that the protection and safety
devices are efficient.
In case of cycles based on food temper-
ature, insert the probe into the food
otherwise the cycle will automatically
switch to time
• Try to switch the unit OFF/ON.
• If the problem persists, Call Service.
• Try to switch the unit OFF/ON.
• If the problem persists, Call Service.
• The machine loses personalization.
Operations can continue.
• If the problem shows up again, Call
Service.
ACTIONS

Advertisement

Table of Contents
loading

Table of Contents